Summary of Contents for Episode ESS-SUB-SNGL-8

  • Page 1 INSTALLATION MANUAL ESS-SUB-SNGL-8 ESS-SUB-ENC-RET-SGL8 ESS-SUB-ENC-IWIC-PCO ESS-SUB-ENC-IW-PCON...
  • Page 2 page | 2 snapav.com Support 866.838.5052...
  • Page 3: Cutout Dimensions

    | 3 INTRODUCTION Thank you for purchasing Episode® Signature speakers. Episode is one of the most highly-regarded brands of speakers available today. We appreciate your business and we stand committed to providing our customers with the highest degree of quality and service in the industry.
  • Page 4 page | 4 Allow space for the bezel if installing near adjacent objects, or cut the hole in two steps as shown below. Cut the drywall at a 45° angle so that if the OBSTRUCTION speaker is too close to an obstruction, you PLUG can easily ‘plug’...
  • Page 5 Adding the Subwoofer to the Retrofit Enclosure Wire the subwoofer to the pigtail contained within the enclosure before installing into the wall. Insert ESS-SUB-SNGL-8 after completing install of the retrofit enclosure(s). IMPORTANT: Be sure to align the dog ears of the subwoofer to the markings shown on the enclosure.
  • Page 6 page | 6 ESS-SUB-ENC-IWIC-PCO (In Ceiling Back Box) Without extention Arms The ESS-SUB-ENC-IWIC-PCO is designed for in-ceiling and in-wall preconstruction applications. This enclosure only fits into a 2"× 6" stud bays and can be used in walls as well. The ESS-SUB-ENC-IW-PCON should be used if the wall is built with 2"...
  • Page 7 To move the subwoofer to the upper location, swap the blank plate with the drywall flange. To convert the enclosure for use with dual subwoofers, replace the blank with the included second drywall flange. BLANK FLANGE © 2019 Episode®...
  • Page 8 page | 8 Adding the Subwoofer to the Enclosure for ESS-SUB-ENC-IWIC-PCO and ESS-SUB-ENC-IW-PCON Complete the instructions below once the drywall has been installed, using the drywall flange to cut out the opening in the sheetrock. 1. Prewire the subwoofer to the pigtails in the enclosure. 2.
  • Page 9 1. Turn each dog screw in a counter- clockwise direction until the dog is in its TIGHTENED original parked position. 2. Once the dogs are disengaged, the Spring subwoofer is easily removed from the ceiling or wall. PARKED © 2019 Episode®...
  • Page 10 | 10 CONNECT It is recommended to pair Episode Signature subwoofers and enclosures with Episode subwoofer amplifiers. The configuration, number of subwoofers, and size of the room presents several amplifier options from which to choose. Small to Medium Room Connection Diagram The EA-AMP-SUB-1D-150 amplifier is recommended for spaces less than 1500 square ft up to 2500 square feet.
  • Page 11 (Sub 1 + Sub 2) Minimum 4 100-120V AC 220-240V AC ESS-SUB-ENC-IWIC-PCO or ESS-SUB-ENC-RET-SGL8 ESS-SUB-SNGL-8 EA-AMP-SUB-1D-500R (LFE) DC 12V TRIGGER FUSE T8AL/250V 100-120V~60Hz/220-240V~50Hz 500WATTS OPERATE SUB 1 Total Impedance SUB 2 UPDATE (Sub 1 + Sub 2) Minimum 4 100-120V AC 220-240V AC © 2019 Episode®...
  • Page 12 SUB 2 SETTINGS MODE POWER MODES 300 (LFE) (Sub 1 + Sub 2) Minimum 4 100-120V AC 220-240V AC ESS-SUB-ENC-IW-PCON ESS-SUB-SNGL-8 (qty. 1) Medium to Large Room Connection Diagram EA-AMP-SUB-1D-500R (LFE) DC 12V TRIGGER FUSE T8AL/250V 100-120V~60Hz/220-240V~50Hz 500WATTS OPERATE The EA-AMP-SUB-1D-500 amplifier is recommended for spaces 1500...
  • Page 13 ESS-SUB-ENC-RET-SGL8 ESS-SUB-SNGL-8 EA-AMP-SUB-1D-500R (LFE) DC 12V TRIGGER FUSE T8AL/250V 100-120V~60Hz/220-240V~50Hz 500WATTS OPERATE SUB 1 Total Impedance SUB 2 UPDATE 100-120V AC 220-240V AC (Sub 1 + Sub 2) Minimum 4 EA-AMP-SUB-1D-500 ESS-SUB-ENC-RET-SGL8 (qty. 4) ESS-SUB-SNGL-8 (qty. 4) © 2019 Episode®...
  • Page 14 Using the front panel of the subwoofer amplifier, select the “Dual8” preset EA-AMP-SUB-1D-500R (LFE) DC 12V TRIGGER FUSE T8AL/250V 100-120V~60Hz/220-240V~50Hz 500WATTS OPERATE SUB 1 Total Impedance SUB 2 UPDATE 100-120V AC 220-240V AC (Sub 1 + Sub 2) Minimum 4 EA-AMP-SUB-1D-500 ESS-SUB-ENC-IW-PCON ESS-SUB-SNGL-8 (qty, 2) snapav.com Support 866.838.5052...
  • Page 15 (Sub 1 + Sub 2) Minimum 4 EA-AMP-SUB-1D-500 ESS-SUB-ENC-IW-PCON (qty,2) ESS-SUB-SNGL-8 (qty, 4) FINE TUNE To fine tune the system, leverage the rear panel of the subwoofer amplifier. EQ settings should be adjusted based on the size of the room and the size of the enclosure.
  • Page 16: Specifications

    | 16 SPECIFICATIONS Product ESS-SUB-SNGL-8 Connector Type Gold-Plated Push Terminals Frequesncy Response 30Hz - 300Hz Nominal Impedance 8 ohms Power Handling 150 W (RMS)/200W (Dynamic) Sensitivity 85 dB Speaker Grille Steel Micro-Perf Mesh / White / low profile thin bezel Woofer 6”...
  • Page 17 Down to 20 Hz Down to 19 Hz Response Speaker Steel Micro-Perf Mesh / Uses grille from Uses grille from Grille White / low profile thin ESS-SUB-SNGL-8 or ESS-SUB-SNGL-8 or bezel Included optional ESS grilles Optional ESS_GRL-DSUB8-RET-WT Optional ESS_GRL- and ESS-GRL-DSUB8- DSUB8-RET-WT and...
  • Page 18: Limited Lifetime Warranty

    | 18 WARRANTY Limited Lifetime Warranty Episode® speakers have a Limited Lifetime Warranty. This warranty includes parts and labor repairs on all components found to be defective in material or workmanship under normal conditions of use. This warranty will not apply to products that have been abused, modified, or disassembled.
  • Page 19 | 19 © 2019 Episode®...
  • Page 20 © 2019 Episode® Rev: 190318-1750...