AIR IN PROPANE SUPPLY LINES

For safety reasons, the refrigerator will attempt to ignite
on propane within a specified amount of time . When
starting the refrigerator for the first time after storage
or after servicing the propane supply system, propane
supply lines may contain air . Due to air in the supply
lines the refrigerator may not ignite on propane within
the specified amount of time . Follow the procedure on
how to remove air from the propane supply lines .
To remove air from the propane supply lines:
Ensure the primary propane shut-off valve is open .
Light cooktop burners first to quickly purge air from
the main distribution line .
Push the On/Off button to turn the refrigerator on .
Press the Mode button until the refrigerator
indicates LP . The refrigerator will begin the ignition
cycle during which the propane safety valve opens
and the igniter sparks .
If the refrigerator fails to light, turn off the
refrigerator to reset the ignition cycle then turn
the refrigerator back on . If after several attempts
the refrigerator fails to light, stop and consult an
authorized Dometic service center .
REFRIGERATOR — RESIDENTIAL
The refrigerator operates from shore power, the
generator or from the inverter . The freezer door is
equipped with water and ice cube dispensers . Ice can
be dispensed as crushed or cubed .
NOTE:
The refrigerator operates on 120 Volts AC, not
from propane .
INFORMATION:
See the refrigerator OEM manual for detailed
information and instructions .
88
Refrigerator Operation from Inverter While
Traveling:
Turn the inverter and refrigerator on . The electrical
combination of the alternator on the engine and the
inverter will supply the power necessary to operate the
refrigerator on 120 Volts AC while traveling .
NOTE:
Be sure to turn the inverter off after travel . Hook
to shore power to continue refrigerator operation .
Refrigerator Operation while Dry Camping:
Start the generator or turn the inverter on to power the
refrigerator . If using the inverter, enable the Automatic
Generator Start feature (through inverter remote) to
avoid dead house batteries and the possibility of food
spoilage . The AGS feature will start the generator
based on parameters set in the inverter remote . See
"Inverter" in Section 8 for information on programming
AGS .

CONTROL PANEL

Features include temperature adjustment for the
refrigerator and freezer . A water filter for the water and
ice dispenser .
On/Off Button:
Press and hold On/Off for three seconds to turn the
refrigerator on or off . This will not disconnect power to
the interior light .
NOTE:
Turning off the refrigerator does not disable
refrigerator power consumption . The refrigerator
must be unplugged to remove power for lighting
and control panel operation .
CAUTION:
Your refrigerator may be supplied with a "travel
strap" or "travel lock" . This strap or lock must be
installed prior to travel . Travel without the strap or
lock attached or engaged may result in damage to
the doors . Damage to the doors is not covered by
the warranty .