About this manual This manual describes how to install the Soluna 15K PACK HV battery system (hereafter referred to as ‘the BS’). Please read the manual in its entirety before installing the BS and follow all instructions throughout the installation process.
The BS should be recycled, not be disposed of with household waste, at the end of its working life. For more information, contact Soluna Australia. There is a risk of physical injury or damage to the BS if the installation requirements are not followed and/or the BS is handled incorrectly.
Response to emergency situations The Soluna 15K PACK HV BS comprises multiple batteries that are designed in such a way as to prevent hazards resulting from failures. However, Soluna Australia cannot guarantee the absolute safety of the BS. Leaking batteries If the BS leaks electrolyte, avoid contact with the leaking liquid or gas.
2. Product introduction The Soluna 15K PACK HV is an NCM lithium battery product with a battery management system (‘BMS’). This high-voltage BS features CAN communication, under-voltage, over- voltage, over-current, over-temperature and under-temperature protection functions. It is characterised by high energy density, long life, safety and reliability and is environmentally sustainable.
Note: retain packaging for future storage or transportation. Packing list The following table lists the numbers of each item included. If anything is damaged or missing, contact Soluna Australia or your distributor. Item Name Remark...
Wiring port The wiring port of the Soluna 15K PACK HV can be seen once the cover cap has been opened (see diagram below for details). Figure 2.3 – Wiring port. Number Name Remark ① CAN1 port For external communication (inverter) ②...
Installation requirements The Soluna 15K Pack HV should be installed against a wall, with eight holes drilled into that wall to fix the racks of the BS. See the following diagram for details. Step 2: screw the bracket to the wall Step 3: install the battery module.
5. Care and maintenance Keep the area around the BS clear of debris. The Soluna 15K Pack HV BS does not require pre-scheduled preventative maintenance – it is not designed to be opened. The unit will be replaced if a failure is diagnosed.