Connection To The Charger; Functions On The Operating Panel; Control Knob; Pilot Function Box (Modeling Lamp) - Priolite M-PACK 500 Instruction Manual

Power pack and flash head
Table of Contents

Advertisement

Instruction manual PRIOLITE M-PACK 500 / M-PACK 1000 (HS) + PRIO HEAD 1000

Connection to the charger

The charging of the battery can be done inside the power pack (switched on or off) or
outside. The charging cable of the supplied charger (16V or 58V, rsp.) is plugged into the
charging socket of the battery drawer and the provided power cable is connected to the
mains outlet. The charging unit is intended for global supply voltages (multi-voltage:
230V/115V). The charging time of a flat battery to full charge is approximately 3 hours. Full
charge is indicated by the lighting up of all 5 LEDs.
The batteries for M-PACK 500 and M-PACK 1000 (HS) are of different size and weight; in
addition, chargers for M-PACK 500 and M-PACK 1000 (HS) are fitted with a 2-pole and 6-
pole charging plug, respectively. They are also provided with a special coding to prevent
damage in case of confusion.
Functions on the operating

Control knob

The control knob is used to set the desired flash power in 1/10 increments from a minimum
of 16V to a maximum of 500J (M-PACK 500) or 1000J (M-PACK 1000 (HS)) covering 6 f-
stops for M-PACK 500 and 7 f-stops for M-PACK 1000 (HS). The output is displayed on the
two-digit 7-segment display in f-stops: 10 stands for maximum power and 5.0 (M-PACK
500) and 4.0 (M-PACK 1000 (HS)) stand for minimum power, respectively. Increasing or
decreasing the f-stop by 1.0 point doubles or halves the flash output, rsp.

PILOT function box (modeling lamp)

The modeling lamp is switched on or off using the "PILOT" buttons.
The PRIO HEAD 1000 designed for the use with the M-PACKs is equipped with a LED
array as energy-saving modeling light.
panel.
PRIOLITE GmbH Wuerzburg - Last revised: 08/2014 - Page 12
M-PACK 500 / M-PACK 1000 (HS) operating panel
From right to left and top to bottom:
PILOT function box (modeling lamp options)
2-digit LED display
Turning knob
Battery drawer with
> Mains switch behind the flap,
> Pull-out handle and upper/lower flap,
> Charging socket and
row of LEDs for charging control (top left)
>
RADIO function box (options for remote control)
1-digit LED-display
Flash release button (TEST)
AUXILIARIES function box (Slave, FC, Audio)