FEATURES

Stainless steel wafer metering station

For ANSI 125 or ANSI 150 flanges

Designed according to BS7350

Tolerance on nominal K

Gost compliant

Class 125
SPECIFICATIONS
Temperature Ratings:
-15ºF to 265ºF
Below 32ºF only for water with
added anti-freezing fluids
Over 212ºF only for water with
added anti-boiling fluids
Body:
Stainless Steel, AISI 316
Extension:
Stainless Steel, AISI 3161
Test point:
DZR Brass, ASTM C35330
Optional features and accessories available for this
Macon product are an extra charge, and not included
in the standard model price.
www.maconbalancing.com
±5%
vs
Tunstall Corporation
118 Exchange Street · Chicopee, MA 01013
Phone (413) 594-8695 · Fax (413) 598-8109
Section: Components
65
Model FMS
Flow Metering Station
Submittal Data
Size
Cvs
Cv
2-1/2"
102.0
175.4
3"
142.2
261.6
4"
249.3
426.3
5"
389.5
654.2
6"
530.2
901.4
8"
929.4
1635.9
10"
1444.0 2497.2
12"
2122.6 3693.7