Advertisement

Quick Links

Customer :
Description :
Customer Part No. :
Delta Model No. :
Sample Date Code:
Sample Issue Date :
Delta Electronics, Inc.
252, Shang Ying Road, Kuei San District
Taoyuan City 33341, Taiwan, R. O. C.
Specification and Manual
Heat Exchanger 190 W/K
HEX180PB
Mar.21.2018
Please send one copy of this specification back after you
signed approval for production pre-arrangement
Approved by :
Date :
Rev.:
Rev : 00
TEL : 886-(0)3-3591968
FAX : 886-(0)3-3591991

Advertisement

Table of Contents
loading

Summary of Contents for Delta HEX180PB

  • Page 1 Specification and Manual Customer : Description : Heat Exchanger 190 W/K Customer Part No. : Rev.: Delta Model No. : HEX180PB Rev : 00 Sample Date Code: Sample Issue Date : Mar.21.2018 Please send one copy of this specification back after you...
  • Page 2: Table Of Contents

    Table of content Packing & Shipping ......................... III Safety Notes ............................. III Product Instruction ........................1 1-1. General Description ......................1 1-2. Main Feature & Model Number ..................1 1-3. Dimension ........................... 2 1-4. Mounting Panel Cutout ..................... 2 1-5. Configuration & Maintenance ..................3 1-6.
  • Page 3: Packing & Shipping

    The document is the exclusive property of Delta Electronics, Inc. it should not be distributed, reproduced, or any other format without prior permission of Delta. Specifications are subject to change without notice.
  • Page 4 Make sure that all wiring is secured, the specified wires are used, and there is no strain on the terminal connections or wires. If refrigerant gas leaks during installation, ventilate the area immediately. Do not directly touch refrigerant that has leaked from refrigerant pipes or other areas, as there is a danger of frostbite. Before serving or cleaning unit, switch power off and disconnect power supply.
  • Page 5 Specification for Approval Customer : Description : Heat Exchanger Customer P/N : Rev. : Delta model no. : HEX180PB Rev. : 00 Sample revision. : Date Code : Sample issue date : Quantity : INTERNAL EXTERNAL...
  • Page 6: Product Instruction

    Built-in Smart Controller Fans N / A Delta High Efficiency Blowers *Note 1 : The cooling capacity (W/K or W/°C) is defined as Q / (TI-TA) Q : Heat dissipation (W) from inside of cabinet TI : Return temperature of internal air circuit (K OR °C) TA : Ambient temperature of external air circuit (K OR °C)
  • Page 7: Dimension

    1-3. Dimension (1) Material : steel sheet SGCC t=1.0mm. (2) Finish : Powder coating 75 μm(MIN.), Color RAL 7035. (3) Dimensional Tolerance : ± 1.0mm [0.04”] 1-4. Mounting Panel Cutout Page 2...
  • Page 8: Configuration & Maintenance

    1-5. Configuration & Maintenance Make sure the HEX surface sealed with mounting flange to avoid water penetrates into shelter through mounting interface. It is suggested to use gaskets sticking on the mounting flange and seal the gap between flange and cabinet with silicone gel during installation.
  • Page 9: Thermal And Airflow

    The refrigerant is environmental friendly product of R134a. Little refrigerant leakage (< 5 g/ year) is allowed for application. If refrigerant leakage seriously, please turn off the power and wait for at least 2 hours to make sure the refrigerant fully exhaust. Please also contact the services to replace spare parts.
  • Page 10: Panel Operation

    Dry contact : (contact max. rating : 60VDC/400mA) User can select dry contact definition both normal open (N.O. Pin3,4) or normal close (N.C.Pin5,4) for alarm output Normal open Normal close Connection Pin 3 & Pin 4 Pin 5 & Pin 4 Control board, NTC and fan are in OPEN CLOSE...
  • Page 11: Environmental Condition

    3. Environmental Condition 3-1. Operating Temperature -20 °C ~ +65 °C (-4 °F ~ 149 °F) 3-2. Storage Temperature -40 °C ~ +70 °C (-40 °F ~ 158 °F) 3-3. Operation Humidity External air loop: 0 ~ 100 % RH Internal air loop: 0 ~ 90 % RH, non-condensing 3-4.
  • Page 12: Accessor

    6. Accessor  Connector : DINKLE 2ESDVM-07P Description Cable wire size -48V 16 AWG 16 AWG Normal open 24 AWG Common 24 AWG Normal close 24 AWG RS485 A port 24 AWG Rs485 B port 24 AWG 7. Installation Notice Check the surrounding obstacles to make sure the product get enough space for air circulate.
  • Page 13: Warranty

    Delta Electronics, Inc., herein referred to as (“products”), will be free from defects in material and workmanship for a period of one (1) year from the date of shipment by Delta Electronics, Inc. This warranty covers repair or replacement of product at the sole discretion of Delta Electronics, Inc.
  • Page 14: Reclaim

    All returns to Delta Electronics, Inc must be securely packed, using original cartons if possible. All returns must have the RMA number visible on the outside of the carton. Delta Electronics, Inc. is not responsible for material damaged in transit.