PROGRAMMING INTERCOM GROUPS
The intercom group must be programmed after you have assigned the type of call button or call code to all the indoor receivers (see Programming Manual
for the DC/01-DVC/01-DC/01ME-DVC/01ME entry panels, code FB00232).
Activating an intercom group
Press PROG ① on the power supply for at least 25 seconds until LED DL2
② flashes quickly.
Then set the RFID PROG jumper ③ to the "+" position.
A
DL1
DL2
Go to an indoor receiver and
press the button with which you
wish to call: a beep will indicate
successful activation.
Repeat the same steps on the
indoor receivers to be added to
the intercom group (max 4 per
group).
To end the procedure, press ① and set the jumper ② to the neutral position.
If no action is performed, the procedure will automatically end after 30
A
DL1
DL2
>25''
+
+
M1
A
DL1
DL2
+
M1
A
DL1
DL2
minutes.
Once an indoor receiver has been included in an intercom group through the
assignment of a call button, it can no longer be excluded from the group.
In order to change the call button for an indoor receiver that has already been
programmed as an intercom, or to add new indoor receivers to the group,
simply repeat the sequence of steps described.
M1
Disabling an intercom group
Press PROG ① on the power supply for at least 25 seconds until LED DL2
② flashes quickly.
Then set the RFID PROG jumper ③ to the "-" position for at least 20 seconds.
To end the procedure, press ① and set the jumper ② to the neutral position.
A
DL1
+
M1
>25''
+
M1
A
A
DL2
DL1
DL2
>20''
+
+
M1
M1