Maintenance
G. Remove the Water Trough
Apply downward pressure on the siphon tube and
remove from the bottom of the water trough.
Remove the upper thumbscrew.
While supporting the water trough remove the two
thumbscrews from beneath the water trough.
Remove the water trough from the bin area.
LOWER
THUMBSCREWS
4-4
UPPER
THUMBSCREW
REMOVE
SIPHON TUBE
H. Remove the ice damper.
ES90/ES130
Grasp left side of ice damper and apply pressure
against the right-hand ice damper mounting bracket.
Pull forward on the ice damper until the left-hand
mounting pin disengages.
Installation
Grasp the right side of ice damper and place left
hand pin in the mounting bracket.
While applying pressure against the left-hand
mounting bracket push the damper until the right-
hand mounting pin engages.
ES170/ES210/ES270
Grasp ice damper and apply pressure toward the left
hand mounting bracket.
Apply pressure to the right hand mounting bracket
with thumb.
Pull ice damper forward when the right hand ice
damper pin disengages.
Installation
Place ice damper pin in left hand mounting bracket
and apply pressure toward the left hand mounting
bracket.
Apply pressure to the right hand mounting bracket
with thumb.
Push ice damper toward evaporator until right hand
damper pin engages.
Section 4