Download Print this page
CyberPower MP60BK User Manual
CyberPower MP60BK User Manual

CyberPower MP60BK User Manual

Surge protection multi-pack

Advertisement

Quick Links

Surge Protection
Surge Protection
Multi-Pack
Multi-Pack
MP60BK/MP61WH/MP62BL
MP60BK/MP61WH/MP62BL
USER MANUAL
CONGRATULATIONS ON YOUR PURCHASE
Thank you for selecting the CyberPower MP60BK/MP61WH/
MP62BL Surge Protection Multi-Pack. This manual explains the
features and operation of the Surge Protection Multi-Pack.
Please take a few moments to read this manual.
Copyright © 2019 Cyber Power Systems (USA), Inc. All rights reserved.
3-Outlet Extension Cord
with 2 USB Ports
P303UBK/P303U/P303UBL
1
2
2-Outlet Surge Protector
P2WUBK/P2WU/P2WUBL
1
Front
Top
3
3
2
Side
EXTENSION CORD INSTRUCTIONS
1. Plug the extension cord into a standard grounding wall receptacle by fully
inserting the plug and ensure that there are no exposed conductors.
2. Make sure the electronic equipment is turned o before plugging into the
extension cord outlets. Do not use extension cords to connect equipment
to the extension cord.
FEATURES
1. Standard Grounded Outlets (3)
2. USB Charging Ports* (2)
Connect and charge up to two (2) USB devices using the surge protected
USB charging ports.
*USB outlets cannot be used as a USB hub. This device does not
transfer data.
SPECIFICATIONS
• Model Number: P303UBK/P303U/P303UBL
• Outlets: Standard Grounded Outlets (3)
• Surge Protection: 350 Joules
• Electrical Rating: 125 V/13 A/1625 W/60 Hz
• USB Charging Rating: 5 V/2.4A shared
• UL Clamping Voltage: UL 1449 4th/900 V (L-N)
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK - Use only in dry locations and
only indoors. DO NOT plug into another relocatable power tap. DO NOT
"daisy chain" extension cords. DO NOT use with any aquarium equipment.
DO NOT use if properly grounded outlets are not available. DO NOT install
this device if there is not at least 10 meters (30 feet) or more of wire
between the electrical outlet and electrical service panel. This device
features an internal protection that will disconnect the surge protective
component at the end of its useful life, but will maintain power to the load –
now unprotected. If this situation is undesirable for the application, follow
the manufacturer's instructions for replacing the device. The conductors
used to connect the SPD to the line or bus and to ground shall not be any
longer than necessary and shall avoid unnecessary bends. DO NOT plug
devices over 2.4A to each USB port.
FEATURES
1. Surge Protected Indicator
Illuminated when the surge protection feature is working properly.
2. USB Charging Ports* (3)
Connect and charge up to three (3) USB devices using the surge
protected USB charging ports.
*USB outlets cannot be used as a USB hub. This device does not
transfer data.
3. Side-Facing Standard Grounded Outlets (2)
SPECIFICATIONS
• Model Number: P2WUBK/P2WU/P2WUBL
• Outlets: Standard Grounded Outlets (2)
2
• USB Charging Rating: 5 V/4.2A total
• Surge Protection: 600 Joules
• Electrical Rating: 125 V/15 A/1875 W
• UL Clamping Voltage: UL 1449 4th/800 V (L-N)
• Maximum Peak Current: 15,000 A
• AC Lines Protected: L-N: 15,000 A
• Response Time: Less than 1 nanosecond
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK - Use only in dry locations and
only indoors. DO NOT plug into another relocatable power tap. DO NOT
"daisy chain" surge protectors. DO NOT use with any aquarium equipment.
DO NOT use if properly grounded outlets are not available. DO NOT install
this device if there is less than 10 meters (30 feet) or more of wire between
the electrical outlet and electrical service panel. DO NOT use for medical or
life support equipment. This device features an internal protection that will
disconnect the surge protective component at the end of its useful life, but it
will maintain unprotected power to the load.
TROUBLESHOOTING
▪ If the protected indicator does not light, the surge protector's AC lines are
no longer protected from surge. The surge protector may have received a
power surge or spike beyond its specified limits that overloaded the
protection circuitry and rendered it inactive. The surge protector has
protected your connected equipment as designed, but it will not protect
against future surges, and spikes. It should be replaced.

Advertisement

loading

Summary of Contents for CyberPower MP60BK

  • Page 1 TROUBLESHOOTING ▪ If the protected indicator does not light, the surge protector’s AC lines are Thank you for selecting the CyberPower MP60BK/MP61WH/ no longer protected from surge. The surge protector may have received a MP62BL Surge Protection Multi-Pack. This manual explains the power surge or spike beyond its specified limits that overloaded the...
  • Page 2 Contact us at: 4. Pack and ship the product to CyberPower and the item(s) of connected Cyber Power Systems (USA), Inc. equipment, a repair cost estimate for the damage to the connected 4241 12th Avenue East, Suite 400 equipment, and all claim forms that CyberPower provides to you.

This manual is also suitable for:

Mp61whMp62bl