Emerson KTM VIRGO N Series Installation, Operation And Maintenance Instructions page 11

Trunnion mounted ball valves
Table of Contents

Advertisement

KTM VIRGO SERIES N TRUNNION MOUNTED BALL VALVES
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
11.3 Series N trunnion mounted ball valve
with gland
Construction: Two-piece
Type: External trunnion
Refer section 11.3.3 for exploded view and
location of parts.
11.3.1 Disassembly procedure
1. Position the valve vertically by resting body
side end flange as shown in Figure 17.
2. Slowly remove the vent / drain plug (20) to
relieve any residual pressure from the body
cavity.
3. Remove nuts (22) and housing (06) from
body (01). Remove fasteners (08), gland (07)
and packing (12) from housing. Remove
O-ring (13) and gasket (14) from housing.
4. Remove key (18 and 19). Remove the stem
(04) from the housing. Remove O-ring (11)
from housing. Remove bearing (23) from
housing, if it requires replacement due
to wear / tear / damage. Remove thrust
washer (24) from stem.
5. Remove trunnion (28) from body by
removing fasteners (33). Remove O-ring (31)
and gasket (32) from trunnion.
6. Disassemble the adapter (02) by removing
nuts (17). Where threaded "Puller Holes"
are provided on adapter flange, appropriate
fasteners can be used to gradually separate
the adapter from the body before lifting. This
can be done by screwing the fasteners in the
puller holes until they touch the body face
and thereby pulling adapter away from the
body. The size of the puller hole threading is
same as that of the fastener (21) size of body
to housing joint. Remove 'O'-ring (09) and
gasket (10) from adapter.
7. Remove seat (05) from adapter. Remove
O-ring (15) from seat. Remove seat springs
(25) from adapter or seat.
8. Remove ball (03) and seat (05) from body.
Remove O-ring (15) from seat. Remove
seat springs (25) from body or seat.
Remove bearing (29) from ball, if it requires
replacement due to wear / tear / damage.
Remove Thrust washer (30) from ball.
9. Where applicable, the sealant injection
fittings (26) may be removed for cleaning.
11.3.2 Re-assembly procedure
1. Ensure all parts are clean prior to assembly
of the valve.
2. Pay attention to references marked during
disassembly.
3. Position the body (01) vertically by resting
on end flange. Insert springs (25) in body or
seat (05). Mount O-rings / lip seals (15) as
applicable on seat and insert seat in body.
4. Assemble bearing (29) and thrust washer
(30) in ball pocket and place the ball (03)
on body side seat such that ball is in closed
position.
5. Insert springs (25) in adapter (02) or
seat (05). Mount O-rings / lip seals (15)
as applicable on seat and insert seat in
adapter.
6. Place gasket (10) and O-ring (09) on adapter.
Place the adapter assembly on body.
Assemble lifting hooks (27) as applicable.
Tighten the nuts (17) in criss-cross pattern.
7. Assemble the trunnion (28) along with
O-ring / lip seal (31) and gasket (32) as
applicable on bodywith fasteners (33).
8. Place O-rings / lip seal (11), packing (12)
and bearing (23) on housing (06). Assemble
gland (07) with fasteners (08).
9. Insert stem (04) along with thrust washer
(24) in housing.
10. Assemble housing along with stem on body
using gasket (14), O-ring (13) and dowel (34).
Tighten the nuts (22) in criss-cross pattern
11. Assemble key (18 and 19) on stem.
12. Assemble drain / vent plug (20) as
applicable.
13. Assemble sealant injection fittings (26) as
applicable.
11