Electrical Requirements - Field Controls VentCool Summit S-Class Series Installation Manual

Hide thumbs Also See for VentCool Summit S-Class Series:
Table of Contents

Advertisement

GRAVITY DAMPER INFORMATION
The VentCool Summit Series fan systems include gravity-closed gravity damper doors that are opened by air
pressure created by fan operation. The dampers serve to block entry of air from the attic into the living space, and
are provided with foam sealing and insulating material in the doors to reduce heat transfer from the attic space.
The Ventcool Summit Series Whole House Fan Systems have di erent gravity damper sizes, depending on
the speci c model to be installed. Verify which gravity damper size is provided with your system prior to
beginning installation of the product.

ELECTRICAL REQUIREMENTS

The VentCool ECM Summit Series Whole-House Fan Systems require a 115 volt electrical power supply
of
minimum 15A ampacity and maximum 15 Amp circuit overcurrent protection. We strongly recommend
providing a dedicated circuit for this fan system. This model has two fan assemblies.
All electrical components, whether included with the VentCool system or supplied by others, must be rated for
the fan system's electrical load requirements; please refer to the VentCool Summit Series speci cations table
for the electrical load requirements of the speci c model to be installed.
All wiring and connections must be made according to this manual and all applicable electrical wiring codes
and standards. All applicable electrical codes must be followed to the satisfaction of the local authority having
jurisdiction.
VentCool Summit Series Whole House Fan Systems are shipped with a pre-wired 20 foot 115VAC power cord
with Nema 5-15P plug and fan control module (FC3JF) prewired and installed on the fan assembly. The fan
assembly directly connects to the Vencool digital wall control (WTT) system via 50 foot Plug&Play (P&P) cable.
The P&P cable is equipped with RJ12 connectors that plug directly into the fan assembly control module
and backside of the wall control display. The wall control display is mounted in the living space and is used
for fan control (on/o , timer operation or temperature operation) of the whole house fan system. Refer to
INSTALLATION: Wiring & Controls section for wiring and connection diagrams for the Ventcool Summit Series
Whole House Fan (Generation 4) product line.
P/N 780104700 03/20 Rev A
page 4 of 20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ventcool summit s6.5Ventcool summit series

Table of Contents