For dealers
When the projector is mounted on the ceiling, a
Sony bracket or recommended equivalent must
be used for installation.
Be sure to secure the cabinet cover firmly when
installing to the ceiling firmly.
Caution
When installing the unit at the angle illustrated, if
the ventilation holes are facing down, install a
metal tray (min. 40 cm × 40 cm (15
3
15
/
")) at the distance indicated below directly
4
under the ventilation holes.
Ensure that foreign materials or liquids do not
drop into the ventilation holes.
Portrait (The buttons
of the unit face down)
Safety precautions for installing the unit on
a ceiling
Never mount the projector on the ceiling or
move it by yourself. Be sure to consult the store
where you purchased the projector or a
dedicated installer.
When installing the unit on a ceiling, be sure to
use a safety wire, etc., to prevent the unit from
falling. For the installation, be sure to consult the
store where you purchased the projector or a
dedicated installer.
30
GB
Precautions
3
/
" ×
4
11
From 50 cm (19
/
")
16
9
to 70 cm (27
/
")
16
Metal tray
On Installation
When installing the unit, leave space between any walls,
etc. and the unit as illustrated.
More than
50 cm
11
(19
/
")
16
Avoid using the unit in a location where the
temperature or humidity is very high, or
temperature is very low.
Avoid installing the unit in a location subject to
direct cool or warm air from an air-conditioner.
Installing in such a location may cause
malfunction of the unit due to moisture
condensation or rise in temperature.
Avoid installing the unit in a location near a heat
or smoke sensor. Installing in such a location
may cause malfunction of the sensor.
Avoid installing the unit in a very dusty or
extremely smoky environment. Otherwise, the
air filter will become obstructed, and this may
cause a malfunction of the unit or damage it.
More than 50 cm
11
(19
/
")
16
More than
50 cm
11
(19
/
")
16

Advertisement