 Turn on the machine
 Set the stitch length to "0.8" and sew 3 stitches.(only on the PFAFF 1591).
 Turn off the machine
 Loosen both screws 1, 2, 3, 4 and 5.
 Bring the needle bar to 2.0 mm after b.d.c. and place the locking pin for the needle bar
 Set the hook point to the centre of the needle, taking care to see that the needle is not
 Adjust needle height according to Requirement 2.
 Adjust hook post according to Requirement 1 and tighten screws 4 and 3.
 Making sure that there is some play in the bevel gear, tighten screws 2.
 With retaining collar 7 touching bevel gear 8 tighten screws 2 and 3.
 Screws 5 remain loose for further settings.
 Adjust needle guard 6 (screw 9) in accordance with requirement 3.
12
Regel
With the needle bar positioned 2.0 mm after BDC and the stitch length set at "0.8"( only
on the PFAFF 1591).
1. the hook point must be at needle centre with a hook-to-needle clearance of 0.05 to
0.1 mm;
2. the top of the needle eye must be 0.8 to 1.0 mm below the hook point;
3. the needle guard 6 must touch the needle lightly.
5
5
4
Fig. 15 - 06
defl ected by needle guard 6.
When the hook is changed, make sure that the markings 10 and 11 are both on
one side.
9
6
1
4
7
(on the PFAFF 1591 and 1593)
10
11
2
3
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

157415911593

Table of Contents