3. SPECIFICATIONS AND ORDERING INFORMATION

3.1 Model Number Ordering Code

QTS - 6
Transmitter Type
Non-Indicating Analog Output
Gas Type
See Sensor Selection Table
Revision
Factory Provided
Enclosure
Industrial: NEMA 4X,7,9 c/w alum. sensor housing E (Note 1)
Industrial: NEMA 4X,7,9 c/w SS sensor housing
Commercial: NEMA 1
Commercial: NEMA 4X c/w Splash Guard
Commercial: NEMA 1 Duct Mount
Options (Enter 0 for no Selection)
Splash Guard
Low Temperature (-40°C) Heater Option (Note 2)
Non-Standard Calibration
Special (Consult Factory)
Note 1:
Chlorine sensor assembly not explosion-proof listed
Note 2: Available only in type N or C enclosures

3.2 Sensor/Transmitter Specifications

Input Power:
Fuse:
Output Signal:
RFI/EMI Protection:
Enclosure Rating:
Encl. Materials:
Sensor Technology:
Response Time:
Sensor Life:
Sensor Gas Types:
B71050-021-000-RB.doc
JUL. 18, 2007
QTS-6000 Series
Analog Transmitter/Sensor
x -
0 0 0
1
X X X
X
S (Note 1)
C
N
D
12 to 36 VDC
0.5 Amp socketed pico fuse
4 to 20 mA DC into 750 ohms
at 24 VDC, Two-wire configuration
4.0 Watt at 1 meter radiated
E - NEMA Type 4X Weatherproof,
Type 7 and 9 Explosion Proof; IP66-68,
Class 1, Div. 1, Groups A, B, C, D
CSA, FM, UL listed; Aluminum
Sensor Housing (also Group A rated)
S - Same as E above except with
316 Stainless Steel Sensor Housing
C, D - NEMA Type 1 General Purpose
N - NEMA Type 4X Weatherproof
E, S - Cast Aluminum, Epoxy Painted
C, N, D - ABS Plastic
Electrochemical, non-consuming
Typical less than 60 seconds for
90% response to a step change
Typical 2 to 3 years
Field configurable for any sensor
from Sensor Selection
S
S
ENSOR
ELECTION AND
G
AS
Transmitter Only
Hydrogen Sulphide
Hydrogen Cyanide
Chlorine
Chlorine Dioxide
Hydrogen Chloride
Sulphur Dioxide
Nitrogen Dioxide
Carbon Monoxide
Nitric Oxide
Hydrogen
Ammonia
Ethylene Oxide
G
Ozone
L
X
Note 3:
- 40°C = -40° F
S
- 25°C = -13° F
- 20°C = - 4° F
Temperature - Sensor:
Temp. - Transmitter:
Humidity - Sensor:
Humidity - Transmitter:
Pressure:
Accuracy:
Repeatability:
Approvals:
3
S
PECIFICATION
M
S
ODEL
TANDARD
S
C
C
(
)
YM
ODE
AL
PPM
---
000
None
H
S
110
0 to 25
2
HCN
115
0 to 20
Cl
120
0 to 3
2
ClO
123
0 to 1
2
HCl
125
0 to 10
SO
140
0 to 6
2
NO
150
0 to 6
2
CO
160
0 to 250
NO
190
0 to 100
H
211
0 to 2000
2
NH
220
0 to 50
3
C
H
O
230
0 to 20
2
4
O
240
0 to 0.5
3
+30°C = + 86° F
+50°C = + 122° F
See Sensor Selection Table
-40° to +50°C (-40° to +122°F)
15 to 90% RH continuous
operating, non-condensing.
0 to 99% RH, non-condensing,
operating and storage
Atmospheric ± 10%
± 2.5% of Reading
± 1.0%
CSA
FM
EE x d II C;
IP68
ATEX 0207 U
ELECTROCHEMICAL TRANSMITTER
PRODUCT MANUAL
T
ABLE
T
EMP
R
ºC
ANGE
(N
3)
OTE
---
-40 to +50
-20 to +50
-20 to +50
-20 to +50
-20 to +50
-20 to +50
-20 to +50
-20 to +50
-20 to +50
-20 to +50
-25 to +30
-20 to +50
-20 to +50

Advertisement

Table of Contents
loading

Table of Contents