Pentair BIOSHIELD 522635 Installation And User Manual page 3

Uv disinfection sterilizer
Hide thumbs Also See for BIOSHIELD 522635:
Table of Contents

Advertisement

IMPORT ANT SAFETY INSTRUCTIONS
IMPORTANT NOTICE
This guide provides installation and operation instructions for the UV
Sterilizer. Consult Pentair with any questions regarding this equipment.
Attention Installer: This guide contains important information about the
installation, operation and safe use of this product. This information should
be given to the owner and/or operator of this equipment after installation
or left on or near the UV system.
Attention User: This manual contains important information that will
help you in operating and maintaining this product. Please retain it for
future reference.
IMPORTANT SAFETY INSTRUCTIONS! PLEASE READ PRIOR TO
INSTALLATION AND OPERATION!
Strictly follow the instructions within this manual to ensure the health and
safety of both, yourself and the UV system. The installation, operation and
maintenance of the UV system can only be carried out after reading and
understanding the information contained in this manual.
The installation of the UV system must be carried out in accordance with
local regulations and codes.
READ AND FOLLOW ALL
INSTRUCTIONS
This is the safety alert symbol. When you see
this symbol on your system or in this manual,
look for one of the following signal words and
be alert to the potential for personal injury.
W arns about hazards that can cause death,
serious personal injury, or major property
damage if ignored.
W arns about hazards that may cause death,
serious personal injury, or major property
damage if ignored.
W arns about hazards that may or can cause
minor personal injury or property damage if
ignored.
NOTE
Indicates special instructions not related to
hazards.
Carefully read and follow all safety instructions in this manual and on
equipment. Keep safety labels in good condition; replace if missing
or damaged.
When installing and using this electrical equipment, basic safety
precautions should always be followed, include the following:
FAILURE TO FOLLOW ALL INSTRUCTIONS AND
W ARNINGS CAN RESULT IN SERIOUS BODILY
INJURY OR DEATH. THIS UV SYSTEM SHOULD BE INSTALLED AND
SERVICED ONLY BY A QUALIFIED POOL SERVICE PROFESSIONAL.
INSTALLERS, POOL OPERATORS AND OWNERS MUST READ
THESE W ARNINGS AND ALL INSTRUCTIONS IN THE OWNER'S
MANUAL BEFORE USING THIS PRODUCT . THESE W ARNINGS AND
THE OWNER'S MANUAL MUST BE LEFT WITH THE POOL OWNER.
Ultraviolet light is damaging to your eyes and
skin! DO NOT handle or stare at an operating UV
lamp. Note that the UV light rays are invisible to the human eye and
precautions should be taken to prevent UV energy from entering the eyes.
ULTRAVIOLET RADIATION. Disconnect all power
from the unit before replacing lamps or servicing
the unit.
The quartz sleeve and or the UV lamp shipped with
this product may have been broken or damaged
during transit. It is therefore essential that the unit be carefully inspected
before connecting to electrical power.
T o prevent possible re or electrical shock, only use
replacement lamps speci ed by the manufacturer.
DO NOT allow system to exceed 50 PSI (Pounds
Per Square Inch).
DO NOT operate this unit above 90 GPM (341 GPM).
Operating the product in this manner may result in
product failure and voiding of warranty.
T o avoid possible electrical shock, special care
should be taken since water is employed in intended
applications. For each of the following situation, DO NOT attempt
repairs yourself. Call Pentair W ater Pool and Spa, Inc. customer service
department at (800) 831-7133 for services or discard the appliance.
If unit falls into the water, DO NOT REACH FOR IT!
First power down the unit and then retrieve it. If the
internal electrical components of the unit get wet, keep the unit powered
down until internal electrical components have dried.
If the unit shows any sign of water leakage,
immediately power down the unit.
Carefully examine the unit after installation. It should
not be powered on if there is water on any part not
intended to be wet.
T o reduce the risk of injury, DO NOT permit children
to use this product.
Bioshield UV systems are designed for low-pressure
water applications DO NOT use these units for any
application outside of their intended use. The use of attachments not
recommended or sold by the original manufacturer may cause unsafe
conditions and may void any warranty.
This unit must be wired in conjunction with
a properly grounded, Ground Fault Circuit
Interrupter (GFCI). Only three (3) wire grounded cables suitable for
outdoor use should be used to connect this unit. If joining cables for
outdoor use, a suitable watertight cable connector must be used. If an
extension cord is necessary, a cord with a proper rating should be used.
A cord rated for less amperes or watts than the appliance's rating may
overheat. Care should be taken to arrange the cord so that it will not be
tripped over or pulled. If in doubt consult a quali ed electrician.
W arping of the UV body may occur when left in
direct sunlight without water inside to help dissipate
the heat.
DO NOT operate the unit in "no- ow" situations.
SAVE THESE INSTRUCTIONS
®
BI OSHI ELD
UV Di si nf ect i on St eri l i zer I nst al l at i on and User' s Gui de
i i

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents