Summary of Contents for Rentokil Lumnia Suspended US
Page 1
Lumnia Suspended US - Instruction Manual Compatible with Lumnia Encapsulation Module This manual is based on the latest information and is provided subject to alteration. We reserve the right to change the construction and/or confi guration of the product and versions at any time without obligation.
1. Safety IMPORTANT SAFETY INSTRUCTIONS WARNING - When using electric appliances, basic precautions should always be followed, including the following: a. Read all the instructions before using the appliance. b. To reduce the risk of injury, close supervision is necessary when an appliance is used near children.
Page 3
1. Safety Warning SAVE THESE INSTRUCTIONS The lamps in this unit produce ultraviolet (UV) light, which can cause skin or eye damage if viewed directly for a long period. Only fit the correct type of UV lamps in the unit. The unit shall be installed and serviced by individuals with appropriate qualifications and/or experience in accordance with national regulations in the country of operation and...
2. Introduction The Lumnia Suspended unit uses three ultra-violet LED driven lamps that attract flying insects that are then captured on a replaceable glue board or encapsulation module. The modular design of this unit allows for both. The Suspended product comes as a glue board monitoring device which can be upgraded to a control device by adding the Lumnia + encapsulation module.
4. Connecting the Power Source NOTE: Cable Assembly not supplied in box. Ordered direct from Rentokil Initial to meet specifi c country requirements. WARNING: You must NOT connect the unit into a lighting circuit. You must connect the power cable to a standard power socket.
5. Installing the Unit NOTE: Before you begin, please contact your Regional Technical Manager for advice on appropriate fi xing and hanging methods. WARNING: When positioning the unit, ensure the hanging height is su cient to clear any equipment below and can be serviced safety. Suspend the unit from a suitable structure at a minimum height of 6’6”...
See Figure 2 below for dimensions to consider when positioning the unit. 11” (280mm) 15.7” (399mm) 21.7” (551 mm) Figure 2: DO NOT position the unit directly over areas where food is handled, prepared, manufactured or where uncovered food is stored. DO NOT position unit directly over sources of heat.
Page 8
7. Preparing the Glue Board Flex Remove Liner 8. Installing the Glue Board 9. Removing the Glue Board...
Page 9
10. Removing and Replacing the UV - LED Lamps NOTE: Please ensure device is in Service Mode before servicing. See Section 4. REMOVING UV LED LAMPS NOTE: Do not touch LED when servicing, maintaining or cleaning the lamps. REPLACING UV LED LAMPS NOTE: Ensure the lamp is pushed fi...
11. User Interface Settings Functions for use with Lumnia ONLY: See Section 15 for Lumnia User Interface Mode Button I = Low II = Med III = High A A A C C C A = Adaptive Low* B = Adaptive Med* C = Adaptive High* * Adaptive Mode: The Adaptive light setting reduces the light output when light levels are below...
Page 11
12. Lumnia Encapsulation Module Your Lumnia Suspended can be turned from a monitoring device to a control device in areas where fl y infestations may occur. A motorised Encapsulation Module can be purchased to use with your Lumnia. Roll included in Box Glue Roll Assembly...
Page 13
Release Click Click Warning: Ensure the encapsulation unit clicks into the bracket as above. The interface is activated when the Lumnia+ Encapsulation Module is inserted. Lumnia User Interface Glue Roll Manual Override Glue Roll Service Day Setting 30 day setting rolls on a clean glue surface every 24 hours Mode Button See Section 11 for Mode Setting User Interface...
Page 14
16. Glue Roll Operation GREEN: OPERATIONAL RED: FAULT 17. Unloading Lumnia Encapsulation See Section 15 for fi tting the Lumnia+ Module NOTE: Counter for Lumnia Encapsulation Module resets when removed from Lumnia. Important that module is removed for a new Glue Roll.
Page 15
18. Servicing: Replacing the Glue Roll Part Part Part Part Part Reuse parts A - E above to create the new Roll Assemblies below New Roll With emboss Without emboss Part Part Part Part Part...
Rentokil reserve the right to alter the specification or design without prior notice. Rentokil cannot accept any liability for any loss or damage arising from the use of any information contained within this manual, or from any incorrect use of the product described herein.
Power supply 100 to 240V AC Power classification Power consumption Ingress Protection Rating IP65 Replacement tubes Rentokil type SKU: 304816 Size W= 21’7” (551mm), H= 11’0” (280mm), D= 15’7” (399 mm) Weight: • Boxed Unit 18.0 Ibs (8.2kg) - (boxed) •...
Page 20
Rentokil reserve the right to alter the specification or design without prior notice. Rentokil cannot accept any liability for any loss or damage arising from the use of any information contained within this manual, or from any incorrect use of the product described herein.
Need help?
Do you have a question about the Lumnia Suspended US and is the answer not in the manual?
Questions and answers