  • Page 1 Above Floor Slide‑out (vertical motor) OEM INSTALLATION MANUAL...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Introduction Safety Resources Required Preparation Installation Room Stop Adjustment Slide Room Installation Mounting and Switch Wiring Post-Installation Check Operation Extending Slide-Out Room Retracting Slide-Out Room Hard Stops Troubleshooting Slide-Out Concerns Syncing the Slide-Out Switch Related Concerns Motor Unit Concerns Wiring Diagram Introduction The LCI Above Floor Slide-out (Vertical Motor) system is a rack and pinion style slide system.
  • Page 3: Resources Required

    Failure to follow instructions provided in this manual may result in death, serious personal injury and/or severe product and property damage, including voiding of the component warranty. Unit MUST be supported per manufacturer's recommendations before working underneath. Failure to do so may result in death or serious personal injury. The “CAUTION”...
  • Page 4: Installation

    Installation Locate the slide-out assembly or assemblies as per OEM design. For a single assembly, center the slide- out assembly (Fig. 1) in the slide-out opening. NOTE: Slide openings are determined by the OEM. Fig. 1 Drive Side Outer Idler Side X-Shaft Drive Shaft Mark the locations of the four mounting bracket's pre-drilled mounting holes for the drive-side...
  • Page 5 Mark the locations of the drive-side (Fig. 3A) and idler-side (Fig. 3B) adjustment assemblies. Mark the location for an access opening on the unit's main floor to accommodate the placement of the vertically mounted drive-side motor (Fig. 3C). Use a 1/2" drill bit to drill the eight mounting bracket through-holes located in step 2. Use a 1 3/8"...
  • Page 6 10. Make sure the slide-out assembly is level prior to installing the slide room. 11. Use the drive-side (Fig. 4A) and idler-side (Fig. 4B) adjustment assemblies to set the slide-out assembly level. This adjustment will correct any tilt in the slide-out. Fig.
  • Page 7: Room Stop Adjustment

    Room Stop Adjustment Adjust the room to desired location as follows: For "out" stop (Fig. 5A) and/or "in" stop (Fig. 5B) adjustment, use a 3/16" hex wrench to loosen the stop's set screw (Fig. 5C) on the stop block (Fig. 5D). Adjust the stop blocks to desired location.
  • Page 8: Slide Room Installation

    Slide Room Installation Place room on top of the hat channel(s) (Fig. 6). Center the room in the slide opening. NOTE: Make sure the room is centered before securing room to hat channel(s). Locate the set of front slide-out mounting holes (Fig. 6), in the hat channels, closest to the front of the slide-out and maintain room alignment.
  • Page 9: Mounting And Switch Wiring

    Mounting and Switch Wiring Depending on OEM requirements, the slide-out room may be operated using a rocker switch (Fig. 7). Determine where to mount the user interface. It can be mounted anywhere inside the unit. The mounting location must be watertight. Install the user interface per OEM recommendations using two OEM-supplied #8 x 1"...
  • Page 10: Operation

    Operation Make sure the unit's T-molding and interior (determined by OEM) are installed prior to operating the slide-out. Make sure the battery is fully charged and hooked up to the electrical system. Extending Slide-Out Room Press and hold the rocker switch in the OUT (Fig. 8A) position until the room is fully extended and stops moving.
  • Page 11: Troubleshooting

    Troubleshooting If, after slide-out assembly and slide-out room installation is complete, slide-out does not perform as expected, make sure the battery is fully charged then for check the following: • Slide rails and rack and pinion are free of dirt, debris or other types of contamination restricting travel. •...
  • Page 12: Syncing The Slide-Out

    Syncing the Slide-Out When the two opposing sides of the slide-out are misaligned—out-of-sync—an adjustment can be made to realign—sync—the system by performing a manual adjustment of the outer x-shaft (Fig. 1). Before accessing the power unit, make sure power to the system has been disconnected. The slide-out adjustment for syncing the LCI Above Floor Slide-out is handled through the drive shaft (Fig.
  • Page 13 Turn the outer x-shaft (Fig. 11) to rotate the drive shaft until the idler-side end aligns—syncs—with the drive-side end. Align the closest hole on the outer x-shaft with the through-hole on the drive shaft (Fig. 11), then reinsert the previously removed (step 2) 1/4" - 20 bolt and locking nut (Fig. 12) to secure the synced slides.
  • Page 14: Switch Related Concerns

    Switch Related Concerns If slide-out moves opposite from what the rocker switch's switch plate indicates, reverse the wires from the motor on the back of the switch. Wire size must be 10 AWG minimum. See Wiring Diagram. NOTE: The use of heat shrinkable butt connectors, a crimp tool and a heat gun may be required to complete the reversed wiring connection.
  • Page 15: Wiring Diagram

    Wiring Diagram NOTE: Wire colors may differ when using a non-Lippert Components switch. Additional wiring MUST use 10 AWG minimum and conform to current RVIA electrical standards. Ground Power Battery Black Ground (Black) Wall Switch Battery Ground Splice Green Battery...
  • Page 16 The contents of this manual are proprietary and copyright protected by Lippert Components, Inc. (“LCI”).  LCI prohibits the copying or dissemination of portions of this manual unless prior written consent from an authorized LCI representative has been provided.  Any unauthorized use shall void any applicable warranty. ...