schmersal AZM300 Operating Instructions Manual

schmersal AZM300 Operating Instructions Manual

Solenoid interlock

Advertisement

Operating instructions
Solenoid interlock
Operating instructions. . . . . . . . . . . .pages 1 to 12
EN
Original
Content
1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.6 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.2 Manual release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.4 Mounting with mounting plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.5 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.6 Actuator and accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .7
5
5.1 Magnet control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
5.2 Mode of operation of the safety outputs. . . . . . . . . . . . . . . . . . . . . .7
5.3 Actuator teaching / actuator detection . . . . . . . . . . . . . . . . . . . . . . .7
5.4 Latching force adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
6
6.1 Diagnostic-LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
7
7.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
7.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
8
8.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
8.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
9
9.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
1.
About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country-specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
EN
AZM300
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AZM300 and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal AZM300

  • Page 1: Table Of Contents

    Operating instructions Solenoid interlock AZM300 Diagnostic function 6.1 Diagnostic-LEDs ........8 6.2 Solenoid interlock with conventional diagnostic output .
  • Page 2: Warning About Misuse

    Emergency exit the line loss. Series-wiring of up to 31 AZM300 … SD components with Emergency exit, distance 8.5 mm serial diagnostics is possible. In devices with the serial diagnostics...
  • Page 3: Technical Data

    Operating instructions Solenoid interlock AZM300 2.5 Technical data Electrical data - Diagnostic output Standards: IEC 60947-5-1, IEC 60947-5-3, ISO 14119, Diagnostic output: ISO 13849-1, IEC 61508, IEC 62061 Switching element: p-type, short-circuit proof Enclosure: glass-fibre reinforced thermo- Utilisation category: DC-12, DC-13...
  • Page 4: Mounting

    Operating instructions Solenoid interlock AZM300 Actuating directions The safety analysis of the guard locking function refers to the component solenoid interlock AZM as part of the complete system. On the customer side further measures such as safe actu- ation and safe cable installation to prevent faults are to be implemented.
  • Page 5: Manual Release

    Operating instructions Solenoid interlock AZM300 After being put into operation, the manual release must be sealed by means of the seal, which is included in delivery. Fault Status Power A: connector plug M12, 8-pole B: LED indications C: Manual release 3.3 Emergency exit -T/-T8 or emergency release -N...
  • Page 6: Actuator And Accessories

    Operating instructions Solenoid interlock AZM300 AZM300...-T/-T8 and -N Mounting plate MP-AZ/AZM300-1 (available as accessory) Device with emergency exit or emergency release 18. 5 Lockout tag SZ 200-1 (available as accessory) 20,5 17,5 23,5 t=3mm 12.5 Ø4 Emergency exit -T 20,5 17,5 Ø10...
  • Page 7: Electrical Connection

    In position II, the latching force is approx. 50 N. 5.1 Magnet control In the power to unlock version of the AZM300, the solenoid interlock is unlocked when the IN signal (= 24V) is set. In the power to lock version of the AZM300, the solenoid interlock is locked when the IN signal (= 24 V) is set.
  • Page 8: Diagnostic Function

    Any error that does not immediately affect the safe functionality of the Evaluation of the diagnostic outputs AZM300 solenoid interlock (e.g. cross-wire short, temperature error, AZM 300 safety output, short circuit to +24 VDC) will lead to a delayed shut-down (refer to table 2).
  • Page 9: Solenoid Interlock With Serial Diagnostic Function Sd

    Operating instructions Solenoid interlock AZM300 Table 2: Error messages / flash codes red diagnostic LED Flash codes Designation Autonomous Error cause (red) switch-off after 1 flash pulse Error (warning) at output Y1 30 min Fault in output test or voltage at output Y1, although the output is disabled.
  • Page 10: Set-Up And Maintenance

    Wiring example 1: Series-wiring of the AZM300 with conventional diagnostic output The voltage is supplied at both safety inputs of the terminal safety component of the chain (considered from the safety-monitoring module).
  • Page 11: Wiring Configuration And Connector Accessories

    Solenoid interlock AZM300 Wiring example 2: Series-wiring of the AZM300 with serial diagnostic function The safety outputs of the first safety component are wired to the safety-monitoring module. The serial Diagnostic Gateway is connected to the serial diagnostic input of the first safety component.
  • Page 12: Eu Declaration Of Conformity

    Philip Schmersal Managing Director The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. K. A. Schmersal GmbH & Co. KG Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Phone:...

Table of Contents