The table below lists the Control Change Numbers and
Names that can be assigned to the various controllers.
Assignable Control Change Numbers and Names
Control Change Number
Name
1
Modulation Depth
5
Portament Time
6
Data Entry MSB
7
Main Volume
10
Panpot
11
Expression
16
General purpose1
17
General purpose2
18
General purpose3
19
General purpose4
38
Data Entry LSB
64
Hold 1(Damper/Sustain) Hold1
65
Portament Switch
66
Sostenute
67
Soft Pedal
71
Harmonic Contents
72
Release Time
73
Attack Time
74
Brightness
80
General Purpose 5
81
General Purpose 6
82
General Purpose 7
83
General Purpose 8
84
Portament Control
91
Reverb Depth
93
Chorus Depth
94
Variation Depth
Others
-------
n
General Purpose: With the CS2x, General Purpose 1 is for FC, 2 is
for Knob 4 (ASSIGN 1/DATA), 3 is for Knob 8 (ASSIGN 2), 4 is for
no setting, 5 is for Knob 2 (DECAY), 6 is for Knob 5 (HPF CUTOFF)
and 7 and 8 are for no setting.
Assigning The Controllers
1. Move the panel controller (i.e. a SOUND CONTROL knob or the
MODULATION wheel) to which the Control Change Number is to
be assigned. The parameters for the controller will appear in the
LCD.
n
LCD
ModDpth
PortaTm
n
DataMSB
MainVol
Panpot
Expres.
Generl1
About The SOUND CONTROL Knobs
Generl2
Generl3
Changes made by the SOUND CONTROL knobs can be output
Generl4
as MIDI messages via the MIDI OUT terminal as assigned using
DataLSB
the ASSIGN CTRL NO function.
PortaSW
Sostnut
The default assignments for the SOUND CONTROL knobs as
Soft
set at the factory are as follows:
Harmonic
Knob 1
RelTime
AtkTime
Knob 2
Bright.
Knob 3
Generl5
Knob 4
Generl6
Knob 5
Generl7
Generl8
Knob 6
PortaCt
Knob 7
Reverb
Knob 8
Chorus
Vari
-------
• When the CS2x receives the data assigned to each SOUND
CONTROL knob from an external MIDI device, the
parameter printed on the panel for the knob will be affected.
For example, when the message for Brightness (74) is
received from an external device, the Attack Time will be
affected when the Brightness (74) is assigned to Knob 1 and
the Attack Time (73) is assigned to Knob 3.
• Both the data assigned to the Knob using the ASSIGN CTRL
NO function and parameter data as printed on the panel for
the Knob are sent to the internal tone generator when turning
the Knob. For example, when you turn Knob 1, both
Brightness (74) and Attack Time will be affected when
Brightness (74) is assigned to Knob 1.
65
Press a [SCENE] button to display the Scene Control parameters.
2. Press ASSIGN CTRL NO [UP/DOWN] button to select the Control
Change Number and Name.
3. Repeat steps 1 and 2 to assign the Control Change Numbers and
Names to each controller.
This function is especially convenient for controlling an external
MIDI device with the CS2x (see page 72).
73: Attack Time
80: General Purpose 5
72: Release Time
17: General Purpose 2
81: General Purpose 6
74: Brightness
71: Harmonic Content
18: General Purpose 3

Hide quick links: