2.1.4.2 PLG100-DX Part Parameter Change
This message sets the PLG100-DX MULTI PART block (see Tables <2-1> and
<2-3>).
2.1.5 DX Parameter Change
11110000
F0H
01000011
43H
0001nnnn
1NH
0ggggghh
GGH
0ppppppp
PPH
0vvvvvvv
VVH
11110111
F7H
2.1.5.1 VCED parameter change
This message sets the VCED block (see Tables <3-1> and <3-2>).
2.1.5.2 ACED parameter change
This message sets the ACED block (see Tables <3-1> and <3-3>).
2.2 Bulk dump
This device uses only the following bulk dump messages.
[XG BULK DUMP]
1) XG System bulk dump
2) Multi Part bulk dump
[PLG100-DX NATIVE BULK DUMP]
1) System bulk dump
2) Part bulk dump
[DX BULK DUMP]
1) VCED
2) ACED
3) VMEM
4) AMEM
2.2.1 XG bulk dump
This message sets XG-related parameters. Unlike parameter change messages,
a single message can modify multiple parameters. The message format is as
follows.
11110000
F0H
01000011
43H
0000nnnn
0NH
01001100
4CH
0sssssss
SSH
0ttttttt
TTH
0ggggggg
GGH
0mmmmmmm
MMH
0lllllll
LLH
0vvvvvvv
VVH
:
:
0kkkkkkk
KKH
11110111
F7H
Address and Byte Count are given in tables <1-n>. Byte Count is indicated by
the total size of the Data in tables <1-n>.
Bulk dump is received when the beginning of the block is specified in "Ad-
dress".
'Block' indicates the unit of the data string that is indicated in tables 1-n as
'Total size'.
Check sum is the value that produces a lower 7 bits of 0 when the Start Address,
Byte Count, Data, and the Check sum itself are added.
2.2.1.1 XG System bulk dump
This message sets the XG SYSTEM block (see Tables <1-1>, <1-2>).
2.2.1.2 Multi Part bulk dump
This message sets the MULTIPART block (see Tables <1-1>, <1-3>).
2.2.2 PLG100-DX Native Bulk Dump
This message sets the special parameters for PLG100-DX. Unlike Parameter
change, one message can modify multiple parameters.
11110000
F0H
01000011
43H
0000nnnn
0NH
01100010
62H
0sssssss
SSH
0ttttttt
TTH
0ggggggg
GGH
0mmmmmmm
MMH
0lllllll
LLH
0vvvvvvv
VVH
:
:
0kkkkkkk
KKH
11110111
F7H
The details are the same as for 2.2.1 XG Bulk Dump. However, see Tables <2-
n> for the Address, Byte Count, and block.
42
Exclusive status
YAMAHA ID
N:Device Number
Parameter Group No.
Parameter No.
Data
End of Exclusive
Exclusive status
YAMAHA ID
N:Device Number
Model ID
ByteCountMSB
ByteCountLSB
Address High
Address Mid
Address Low
Data
Check-sum
End of Exclusive
Exclusive status
YAMAHA ID
N:Device Number
Model ID
ByteCountMSB
ByteCountLSB
Address High
Address Mid
Address Low
Data
Check-sum
End of Exclusive
2.2.2.1 PLG100-DX System Bulk Dump
This message sets the PLG100-DX SYSTEM block (see Tables <2-1>, <2-2>).
2.2.2.2 PLG100-DX Multi Part bulk dump
This message sets the PLG100-DX MULTI PART block (see Tables <2-1>, <2-
3>).
2.2.3 DX bulk dump
Exclusive status
11110000
F0H
YAMAHA ID
01000011
43H
N:Device Number
0000nnnn
0NH
0ttttttt
TTH
Format No.
0sssssss
SSH
ByteCountMSB
ByteCountLSB
0ttttttt
TTH
Data
0vvvvvvv
VVH
:
:
Check-sum
0kkkkkkk
KKH
11110111
F7H
End of Exclusive
Address and Byte Count are given in tables <3-n>. Byte Count is indicated by
the total size of the Data in tables <4-n>.
Bulk dump is received when the beginning of the block is specified in "Ad-
dress".
"Block" indicates the unit of the data string that is indicated in tables 3-n as
"Total size".
Check sum is the value that produces a lower 7 bits of 0 when the DATA, and
the Check-sum itself are added.
2.2.3.1 VCED Bulk Dump
This message sets the VCED block (see Tables <4-1> and <3-2>.
2.2.3.2 ACED Bulk Dump
This message sets the ACED block (see Tables <4-1> and <3-3>.
2.2.3.3 VMEM Bulk Dump
This message sets the VMEM block (see Tables <4-1> and <4-2>.
2.2.3.4 AMEM Bulk Dump
This message sets the AMEM block (see Tables <4-1> and <4-3>.
3. Realtime Messages
3.1 Active Sensing
a) Send
Do not send.
b) Receive
After FE is received one time, if the MIDI signal does not come within 400
msec, PLG100-DX will act the same as when ALL SOUND OFF, ALL NOTE
OFF, and RESET ALL CONTROLLERS are received, and return to the condi-
tion where FE has not been received once.
<1-1>
Parameter Base Address
MODEL ID = 4C
Address
Parameter
(H)
(M)
XG SYSTEM
00
00
00
00
00
00
MULTI PART
08
00
08
0F
MULTI PART
0A
00
(additional)
0A
0F
PART ASSIGN
70
02
Description
(L)
System
00
XG System On
7E
All Parameter Reset
7F
Multi Part 1
00
:
00
Multi Part 16
00
Multi Part 1
:
:
Multi Part 16
00
00
PLG100-DX Part Assign

Advertisement