7 .
For luminaire with asymmetric optics, rotate the fixture
according to arrow mark on the dome towards the
street side. (Figure 18.)
8.
Install six 3/8-24 x3/8" set screws to hold the luminaire
on arm tenon and tighten to 160 inch-lbs.
9.
Install six 3/8-24 x 3/16" jam screws and tighten to 160
inch-lbs.
CAUTION
Over tightening screws may cause fixture damage.
E. Wall Mount
1.
Using wall mount plate as template, drill four holes in
the wall (Figure 19). Install appropriate wall anchors (not
provided). Silicone caulk around the junction box and
wall anchors.
2.
Align the gasket and wall mount bracket on the wall
and pull supply wires through the center holes in the
wall or junction box.
3.
Secure the wall plate to the wall with four 1/2-13 x
1-1/2" long bolts and six lock washers. Torque bolts to
37 ft. lbs.
N
otee:
Make sure the wires do not get pinched and
screws do not get over-tightened.
STREET SIDE
Street Side
Figure 18.
Lock Washer
Hex
Head
Screw
Figure 19.
4.
Loosen and take off the cap from single support arm's
bottom hole. (Figure 20.)
5.
Extend supply wires from junction box to minimum of
3' in length.
6.
Pull extended supply wires through the arm into the
hole where cap was placed (Figure 20.) and hook the
arm over installed wall plate.
N
otee:
7 .
Secure the arm by tightening the two screws on
bottom to approximately 17 ft lbs. towards the wall
plate. (Figure 20.)
Arrow mark on
the dome
Supply Wires
Figure 20.
COOPER LIGHTING SOLUTIONS IB516001EN
Installation Instructions – Arbor Post Top
Flat Washer
Single
Support

Wall Mount

Bracket
Make sure wires do not get pinched.
Cap
Wall
Supply
Wires
Gasket
Single Support Arm
Socket Head
Cap Screws