Download Print this page
Davey DC10 Installation And Operating Instructions

Davey DC10 Installation And Operating Instructions

Sump pump

Advertisement

Quick Links

Sump Pump
Installation and
Operating Instructions
MODELS
DOUBLE CASE:
DEWATERING:
VORTEX:
TWIN IMPELLER: D42, D53
Suffix:
Voltage:
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
CAUTION: This pump MUST be installed with a suitable earth leakage circuit breaker (E.L.C.B.) or
residual current device (R.C.D.) with a rated residual operating current <30mA.
The oil in the seal chamber should be periodically checked and replaced. This work should
be done by a suitably qualified Davey Service Dealer every 2,000hrs of operation or every 12
months, whichever occurs first.
Please pass these instructions on to the operator of this equipment.
DC10, DCS40, RS250, RSD400
D10, D15, D25, D40
D15V, D25V, D40V
A
=
Automatic Float Switch Fitted
M
=
Manual (D75 Models only)
220/250V 50Hz Single Phase

Advertisement

loading

Summary of Contents for Davey DC10

  • Page 1 (R.C.D.) with a rated residual operating current <30mA. The oil in the seal chamber should be periodically checked and replaced. This work should be done by a suitably qualified Davey Service Dealer every 2,000hrs of operation or every 12 months, whichever occurs first.
  • Page 2 All single phase models have automatic reset thermal overload protection built in, ie. should overload on motor cause thermal to open circuit and switch motor off, it will automatically reset and switch the motor on when the motor has cooled down sufficiently, usually within a few minutes. NOTE: If the cord is damaged, the appliance should be repaired by a qualified Davey Service Centre. The supply cord must only be replaced by a suitably qualified person with a genuine Davey replacement supply cord.
  • Page 3 Pump runs for short periods only (the overload protection has tripped): Some foreign body is clogging the impeller.  The liquid temperature is too high.  Pump operating in non submerged position or with no water movement around motor (not applicable to DC10).  Electrical fault.  Do not run the pump dry as this will damage the seal and reduce the life of the pump. Where hair, lint or other string-like material may be in the water, the pump should be regularly checked. It might become necessary sometimes to clean the suction strainer, impeller and/or discharge pipework.
  • Page 4 Davey at the address listed below. On receipt of your claim, Davey will seek to resolve your difficulties or, if the product is faulty or defective, advise you on how to have your Davey product repaired, obtain a replacement or a refund.

This manual is also suitable for:

Dcs40Rs250Rsd400D10D15D25 ... Show all