Page 1
(R.C.D.) with a rated residual operating current <30mA. The oil in the seal chamber should be periodically checked and replaced. This work should be done by a suitably qualified Davey Service Dealer every 2,000hrs of operation or every 12 months, whichever occurs first.
Page 2
All single phase models have automatic reset thermal overload protection built in, ie. should overload on motor cause thermal to open circuit and switch motor off, it will automatically reset and switch the motor on when the motor has cooled down sufficiently, usually within a few minutes. NOTE: If the cord is damaged, the appliance should be repaired by a qualified Davey Service Centre. The supply cord must only be replaced by a suitably qualified person with a genuine Davey replacement supply cord.
Page 3
Pump runs for short periods only (the overload protection has tripped): Some foreign body is clogging the impeller. The liquid temperature is too high. Pump operating in non submerged position or with no water movement around motor (not applicable to DC10). Electrical fault. Do not run the pump dry as this will damage the seal and reduce the life of the pump. Where hair, lint or other string-like material may be in the water, the pump should be regularly checked. It might become necessary sometimes to clean the suction strainer, impeller and/or discharge pipework.
Page 4
Davey at the address listed below. On receipt of your claim, Davey will seek to resolve your difficulties or, if the product is faulty or defective, advise you on how to have your Davey product repaired, obtain a replacement or a refund.