PEAK COMMUNICATIONS DBUH Series Installation And Operating Handbook page 18

Dual hot swappable converters/ line amplifiers /test loop translators
Table of Contents

Advertisement

Instruction 22 (Module Reconfiguration Requests)
The unit MUST be in remote mode to allow reconfiguration of parameters via the remote control. Setting the unit in
Remote mode can be done either by the front panel or remotely using the instruction 24.
Due to the ability of the DBUH/DLAH/DTLH to accept differing module types into it, the module status request reply
may vary between these different channel types.
Message
Byte No.
1
2
3
4
5
6
8
12
13
Instruction 22 (System Reconfiguration Requests)
The unit MUST be in remote mode to allow reconfiguration of parameters via the remote control. Setting the unit in
Remote mode can be done either by the front panel or remotely using the instruction 24.
This message should only be used with units with the mute option fitted.
Message
Byte No.
1
2
3
4
5
6
7
8
Instruction 24 (Set Remote/Local Mode)
Message
Byte No.
1
2
3
4
5
6
7
Issue 3.20
Set Value /
(example)
02
?
?
22
'M'
'01'
'+123'
?
03
Set Value /
(example)
02
?
?
22
'S'
'M'
?
03
Set Value /
(example)
02
?
?
20
'R'
?
03
DBUH / DLAH / DTLH Installation and Operation Handbook
Length
(bytes)
1
STX
1
No of bytes in message
1
Address
1
Message instruction
1
Module
2
Module number
4
Attenuation in 0.1 dB steps
'+123' = 12.3dB
1
Checksum
1
ETX
Length
(bytes)
1
STX
1
No of bytes in message
1
Address
1
Message instruction
1
System
1
Wanted mute status
'U' = Unmuted
'M' = Mute
1
Checksum
1
ETX
Length
(bytes)
1
STX
1
No of bytes in message
1
Address
1
Message instruction
'R' = Remote Mode
1
'L' = Local Mode
1
Checksum
1
ETX
Description