CONNECTION
Take care that when using the products in series connection, the applied air pressuredrops
gradually unit by unit. (The volume of the drop depends on the connected tube length.)
Use the optional series connection set (ER-VWAR80) for series connection (One
set per unit is required). The maximum No. of the connectable units is 5 (Including
this unit). When using the units in series connection, fit the end connector on the
connector for series connection of the unit connected to the end. Even if only one
unit is used, fit the end connector on the connector for series connection.
Fit the air inlet fitting (enclosed with the series connection set) after taking the sealing
cap off with a hexagonal wrench. The tightening torque should be 0.5N・m or less.
Note that the gasket is fit in the air inlet. Be sure to tighten the fitting with the gasket.
When using the units in series connection, make sure that the air pressure around
the air inlet of each unit is appropriate.
Power supply / I/O connector (8-way)
Connector for series connection (9-way)
Connection cable
(Accessory)
Cable for series connection
Enclosed with the series
connection set (ER-VWAR80)
(Optional) (1 pc./set)
8
I/O DIAGRAM
9
8
7
6
4
3
[F.G.]
2
[0V]
1
[+V]
Terminal No. of the power supply / I/O connector
Color code of the connection cable
(Brown) +V
(White)
D
1
Discharge state output
T
r1
50mA max.
Z
D1
(Black) Error output
T
r2
Z
D2
(Orange) Check output
T
r3
Z
D3
5V
(Violet) Reset input
4.7kΩ
D
2
5V
(Pink) Discharge halt input
4.7kΩ
D
3
(Blue) 0V
(Green / Yellow) F.G.
Internal circuit
Users'circuit
Symbols...D
Reverse supply polarity protection diode
1:
D
D
Input protection diode
2,
3:
Z
, Z
, Z
Surge absorption zener diode
D1
D2
D3:
Tr
NPN output transistor
,T
,T
1
r2
r3:
Connector pin arrangement
Power supply / I/O connector
①②③④⑤⑥⑦⑧ 1 2 3 4 5 6 7 8 9
9
INPUT SIGNAL CONDITIONS
● Conditions for the discharge halt input and the reset input are as follows.
・ Discharge halt input
Open
DSC OFF
(Low input)
Low
Note: Repeat control with 'DSC OFF' input should be 1Hz or less.
Note that the continuous discharge for 2 sec. or more is required for stable detection of check
output. (CHECK). In case of using with the continuous discharge for less than 2 sec. again
and again, confirm the check output (CHECK) with the continuous discharge for 2 sec. or
more when maintenance is carried out.
OPERATION MATRIX
10
Indicators (
:Light up,
Power
Discharge
Air monitor
(POWER)
(DSC)
(AIR) (Note 1)
Green
Green
Orange
Normal (with air)
Normal (without air)
Check
Opera-
t i o n
Error
s t a t e
Discharge halt input
Reset input
(Maintained)
(Maintained)
Air inlet fitting [Enclosed with the series connection
set (ER-VWAR80) (Optional) (1 pc./set)]
Air tube (φ6mm)
(Please arrange separately)
Sealing cap
End connector
(Accessory)
Connector for series connection (9-way)
In case of use solely, be sure to fit the
end connector (optional).
Load
Load
Load
50mA max.
50mA max.
*1
*1
*1
Non-voltage contact or NPN open-collector transistor
or
Discharge halt input
Low (0V): Discharge halt
High (Open): Discharge allowed (Operation starts)
Reset input
I
n the state that operation is stopped due to an
error detection, open 0V of the power supply from
short-circuit state to cancel ERROR.
Connector for series connection
・ Reset input
10ms
0.5 sec.
or more
or more
Open
RESET
(Start-up input)
Low
Output
:OFF)
Check
Error
Discharge
Check
(CHECK)
(ERROR)
state
Orange
Red
N.C.
N.O.
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
(Maintained)
(Maintained)
(Maintained)
Notes: 1)
The air monitor function is to monitor the supplied air pressure. If the air pressure falls less
than 0.02MPa approx., the discharge from the needle stops and the indicator lights up. If
the air pressure rises again after the pressure fall was detected, discharge starts again.
2)
The air monitor function always check the air pressure and independent from the other functions
(ERROR, CHECK or the discharge halt input). Thus, even in the state that the discharge was
stopped by another function, if the air pressure falls, the air monitor indicator (orange) lights up.
3)
In the state that the discharge from the needle stops, such as when the air pressure fall is detected
or while the discharge halt input is input etc., CHECK and ERROR detection function do not operate.
4)
The discharge halt input is invalid in error state. CHECK function doesn't operate as well.
5)
When the discharge from the needle stops due to the air monitor function, the discharge
halt input or ERROR detection function, the detection result by CHECK function is erased.
The detection is carried out again when the discharge from the needle restarts.
6)
Remove the cause of error, and then reset the unit. In case the cause of error has not been
removed, the unit goes into the error state again.
7)
In order to reset the unit in error state, turn the power off and on again.
8)
In case the discharge from the needle is controlled in the state that air is supplied, CHECK
may be output temporarily due to a transitional state of the discharge phenomenon.
However, the charge removal capability remains the same.
11
MAINTENANCE
Make sure to turn off the applying air and the power supply while inspection,
cleaning or maintenance is carried out.
Before loosening the nozzles for maintenance etc., be sure to stop applying air.
Otherwise, the discharge needle unit may be flew by the air pressure.
If dirt, such as dust, etc., is stuck on and around the discharge needle or inside
the nozzle depending on the environment of use, the charge removal effect
deteriorates. Clean those areas periodically, as a reference, once a week.
However, when using this product in the environment exposed to too much dust,
be sure to clean up the discharge needle frequently.
The discharge needle is a part having a product life time. It is recommended that
the needle should be replaced, as a reference, after 10,000 hours in use. When
the needle is replaced, replace the discharge needle unit (optional).
Procedure for cleaning and replacing the discharge needle nit
Unscrew the discharge needle counterclockwise.
Remove dirt on and around the discharge needle, inside the
nozzle and inside the tube fit in the nozzle with a cotton bud
soaked in absolute alcohol. Particularly, clean inside the tube
fit inside the nozzle and around the discharge needle
thoroughly such that any dirt or grease doesn't remain there
(refer to the right figure), or the charge removal capability
may deteriorate. Remove / fit the discharge needle along the
guide groove on the air outlet of the main body.
After cleaning, screw the nozzle clockwise. Tighten the
nozzle by hand till it stops and then confirm that the nozzle
doesn't move. If the nozzle is not tightened enough, the
charge removal capability may deteriorate or the nozzle may
come off.
+
24V DC
TROUBLE SHOOTING
12
-
Always be sure to turn off the power before checking the discharge part.
problem
Air monitor
Air is not
("AIR")
supplied
indicator(oran
Air pressure
ge) lights up
drops
Nozzle is
loose
Discharge
Check
needle is dirty
("CHECK")
Discharge
indicator (orange)
needle is worn
F.G. is not
connected
Condensation
Condensation
Error
Foreign part
("ERROR")
F.G.
indicator (red)
connected
Nozzle is loose
Doesn't go back to
Cause is not
removed
normal state by reset
INTENDED PRODUCTS FOR CE MARKING
13
The models listed under "
Marking.
10ms
As for all other models, please contact our office.
or more
Contact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
14
CSA/UL compliant product
Discharge
● This product complies with CSA and UL standards, and has been certified by TUV SUD.
t h r o u g h
Error
n e e d l e
Corona
N.C.
discharge
ON
ON
http://panasonic.net/id/pidsx/global
ON
OFF
Overseas Sales Division (Head Office)
ON
ON
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
OFF
OFF
Phone: +81-568-33-7861 FAX: +81-568-33-8591
ON
OFF
About our sale network, please visit our website.
ON
(Allowed)
PRINTED IN JAPAN
WARNING
WARNING
Cause
Remedy
Make sure that the supply voltage is within the specifications.
Make sure that the air pressure is not lower than the specified
value (0.05MPa) around this product.
Make sure that the air tube is inserted to the air inlet fitting firmly.
Make sure that the supply voltage is within the specifications.
Check the tip of the discharge needle for chip and contamination, and make
sure that the discharge needle unit is mounted properly on the main body.
If the CHECK indicator (orange) lights up even after cleaning the
discharge needle, also check the nozzle part for contamination.
Make sure that the nozzle is mounted properly.
Make sure that the applied air pressure is within the specifications.
Check whether the F.G. terminal is connected.
Make sure that the supply voltage is within the specifications.
Abnormal discharge is possible.Turn off the power supply, check the tip of the
is
not
discharge needle for chip and contamination, and make sure that the discharge
needle unit is mounted properly on the main body. Also, check the inside of the
nozzle for foreign objects, and make sure that the nozzle is mounted and
installed properly.
・Check that the cause of 'CHECK' or 'ERROR' is removed.
3
SPECIFICATIONS" come with CE
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
Guide groove
(ER-VW)
Discharge
needle unit
Guide
Nozzle
Clean the shaded area
Tube fit inside
the nozzle
(
(
(
(
Cross-section view
Front view of
of nozzle
discharge needle unit