5) Operation of device
5. Operation by external signal
UD40 controller can be controlled by external devices by sending signals into "External I/O" connector on the back
side of control unit.
1. Pin-out and descriptions for External I/O connector (D-Sub37)
Pin No.
I/O
Signal name
1
Local / remote switching
2
LED lighting
3
Program No. change pulse
4
Program No. bit - 0
5
Program No. bit - 1
6
Program No. bit - 2
7
Program No. bit - 3
8
Program No. bit - 4
9
LED - 1 ON
10
LED - 2 ON
11
LED - 3 ON
12
LED - 4 ON
13
LED - 5 ON
14
NC
15
Reserve input - 1
16
Reserve input - 2
17
External emergency stop - 1
18
External emergency stop - 2
19
Common input
20-28
NC
29
Equipment power ON
30
LED radiation ready
31
LED radiation underway
32
Warning
Occurrence of equipment
33
error
Equipment main unit under
34
emergency stop
35
Reserve output - 1
36
Reserve output - 2
37
Common output
*1
Shorted with common input
*2
One-shot pulse with 0.3sec or longer shorting with common input
*3
Shorted state with common output
*4
Open state with common output
Content
Enable external signal control (remote control) when ON
Light LED head under selected program conditions when ON
Modify program No. by one-shot ON
Designate LED lighting program No.
Set program No. with total of 5 bits (32 ways).
Set program contents from touch screen.
Light block 1 of LED head when ON
Light block 2 of LED head when ON
Light block 3 of LED head when ON
Light block 4 of LED head when ON
Light block 5 of LED head when ON
Not connected. (not used.)
Reserve input
Reserve input
Device goes to emergency stop when OPEN.
(Dry contacts independent from other signals must be used for his
signal.)
Common for Nos. 1 to 16 signals (for input)
Not connected. (not used.)
*3
ON
when power is fed to device (ON
occurrence of errors as well)
*3
ON
when LED radiation is possible (OFF
blocks, at the time of errors)
*3
ON
at the time of LED radiation (OFF
on all blocks)
*3
ON
when LED or fan reaches end of life warning status
*4
OFF
at the time of device errors (content of error to be checked
on touch screen)
upon emergency stop on device's main unit
*4
OFF
Reserve output
Reserve output
Common for Nos. 29 to 36 signals (for output)
- 30 -
*1
*1
*2
signal.
*1
*1
*1
*1
*1
*3
to be maintained upon
*4
during radiation on all
*4
only when lights are off