Table of Contents

Advertisement

4.
Dispense fluid B as follows:
a.
Place a clean 1 quart (1000 cc) container under
sampling valve H
b.
Slowly open and adjust sampling valve H
achieve desired flow. The pump stops automati-
cally after 5 cycles. Indicator B turns off.
310665E
B
.
B
5.
Close sampling valve H
6.
Compare fluid amounts in the containers; they
should be about equal. Repeat test if fluids are not
equal. If problem persists, see Troubleshooting in
Xtreme Mix 185 Repair Manual.
to
If pump fails any of pump stall tests, alarm will dis-
play (see alarms 15-20, page 34).
Pump Test
B
.
25