Download Print this page

Sundstrom SR 63 Operating Instructions Manual

Compressed air hood
Hide thumbs Also See for SR 63:

Advertisement

Quick Links

Operating instruction
SR 63
Compressed air hood
Revision: 02
OI03H-0318 SR 63
1
2020-06-04

Advertisement

loading
Need help?

Need help?

Do you have a question about the SR 63 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sundstrom SR 63

  • Page 1 Operating instruction SR 63 Compressed air hood Revision: 02 OI03H-0318 SR 63 2020-06-04...
  • Page 2: General Information

    Sundströms compressed air hood SR 63 is a continuous flow compressed air line breathing apparatus in approved according to EN 14594:2005, 3A/3B. When selecting equipment for SR 63 some of the factors that should be considered are as follows: • Type of pollutant •...
  • Page 3: Breathable Air

    • the air shall have a sufficiently low dew point to avoid internal freezing of the equipment. In the event of uncertainty as to whether the above demands have been met, a filter such as the Sundström type SR 99-1 compressed air filter should be connected. OI03H-0318 SR 63 2020-06-04...
  • Page 4 Unpacking the SR 63 Packing list: • Hood with breathing hose • Control valve • Belt • Flow meter • Protective film • User instructions OI03H-0318 SR 63 2020-06-04...
  • Page 5: Functional Check

    • The float can move freely. go, in order to throttle the air • The air supply is not flow rate to a minimum. restricted by kinks or other restrictions in the hoses. OI03H-0318 SR 63 2020-06-04...
  • Page 6 Unroll the compressed air 150 l/min, while in the fully tube and make sure that it is open position (turn clockwise), not twisted. it is around 240 l/min. Connect the tube to the control valve inlet. OI03H-0318 SR 63 2020-06-04...
  • Page 7 Turn the knob half that engages in one of clockwise to reduce the width the holes in the upper half and anti-clockwise to increase it. OI03H-0318 SR 63 2020-06-04...
  • Page 8 4.2 In emergency situations, 4.4 Pull the locking ring back. the neck strap can be released without releasing the buckle: Grip the neck strap with one hand on each side of the buckle and pull firmly. OI03H-0318 SR 63 2020-06-04...
  • Page 9 5.2 Pull off the 8 rubber studs 5.4 Place the hood over the and remove the frame and frame and insert the 4 studs visor. into the corresponding holes in the hood. OI03H-0318 SR 63 2020-06-04...
  • Page 10 Secure with the studs, oriented into the guide holes possibly using a pair of pliers. in the visor. OI03H-0318 SR 63 2020-06-04...
  • Page 11 6.2 Release the hose from 6.4 By pulling the hose, check the hood by cutting off the that it is firmly secured to the hose clip with a pair of hood. nippers OI03H-0318 SR 63 2020-06-04...
  • Page 12 Then wash with dishwashing detergent solution, rinse and leave to dishwashing detergent or the dry. like. Rinse and leave to dry. After cleaning, store the equipment in a dry and clean area at room temperature. Avoid direct sunlight. OI03H-0318 SR 63 2020-06-04...
  • Page 13: Maintenance Schedule

    The schedule shows the recommended minimum maintenance Before use After use Annually procedures required in order to ensure that the equipment is always • • • Visual inspection in functional condition. • • Functional check Cleaning • Change of breathing hose • OI03H-0318 SR 63 2020-06-04...