Disassembly Instructions
1. Ensure that the pump has been isolated and that there is no static energy within the pump system (i.e.
that the discharge is not pressurised).
2. Remove the cable gland, and internally disconnect the cable.
3. Lay the pump on its side, with the oil drain plug lowermost over an oil collection vessel.
4. Unscrew the oil plug allowing the oil to drain into the vessel ready for safe disposal in accordance with
local guidelines and regulations.
5. Remove the nuts and washers on the strainer underside and take off the strainer (and bottom plate
where present).