  • Page 1 VDR / S-VDR Voyage Data Recorder System Operation Guide www.amimarine.com...
  • Page 2 AMI Marine Limited Technical details contained in this publication are subject to change without prior notice Page 2 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 3: Table Of Contents

    Incident Marker ......................26 Consumables Notifications ....................27 Consumables Due ............................27 Consumables Over Due ..........................28 System Maintenance Schedule ........................29 Document Issue Details .......................30 Warranty Form ........................32 Page 3 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 4: Important Notices

    AMI Marine. AMI Marine shall not be held liable for any damage caused to the system due to the introduction of any virus or malware, or any other damage caused by an unauthorised USB device.
  • Page 5 Page 5 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 6: Terms And Definitions

    Dedicated reserve power source A battery, with suitable automatic charging arrangements, dedicated solely to the VDR, of sufficient capacity to operate it for a minimum of 2 hours. Page 6 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 7 Any sensor or device external to the VDR, to which the VDR is connected and from which it obtains signals and data to be recorded Page 7 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 8: Abbreviations

    Video Electronics Standards Association Video Graphics Array Voyage Data Recorder X16-A 16 input Analogue to Serial NMEA Interface X32-D 32 input Digital to Serial NMEA Interface Page 8 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 9: Product Introduction And Overview

    Product Introduction and Overview AMI’s new “X2” VDR / S-VDR and the associated interfaces have been developed using expertise gained over two decades in marine electronics design, interfacing and retransmission. The result is a system designed and built in the UK that not only meets the mandatory regulations, but offers more flexibility, functionality and features to the end user than ever before.
  • Page 10 MIC-0005 - External MIC-0006 - Internal The X2 microphones have been designed with high quality audio and easy installation in mind. Using noise reducing 600Ω balanced audio for the clearest possible recording the audio clarity is second to none. The built-in auto test ensures all microphones are functioning correctly, giving a visual indication on the TSM in the event of a failure.
  • Page 11: Main Application And User Interface

    Power LED – This will illuminate when the key is turned to the ON position. Recording LED – This will illuminate when the X2 application is running. Fault LED – Only illuminates when there is a hardware fault or the door is open.
  • Page 12 Once the system has completed the boot sequence the HOME screen will be displayed as below Pressing one of the tabs on the navigation menu at the left of the screen will open the corresponding screens. Page 12 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 13: Home Screen

    Tapping the ‘Incident Marker’ (twice) will add a line into the log file for quick reference during data analysis Both of these controls are available on under all tabs Page 13 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 14: Video Screen

    Within the Video page thumbnails of the RADAR/ECDIS video can be seen showing the current images being captured. User Control: Tapping the individual thumbnail will allow the chosen image to fill the window. Page 14 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 15 YELLOW. Once acknowledged the VIDEO status side bar will stop flashing but remain YELLOW, the thumbnail frame will remain YELLOW until the issue is cleared. Page 15 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 16: Audio Screen

    The self-test is undertaken by way of a beep test, which will be heard via each individual microphone during the automatic and manual self-tests The screen above shows each channel’s received audio level and the current status of each microphone. Page 16 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 17 Once the audio level has been tested and is an acceptable level the indication will revert to green. User Control: Tapping the microphone status indicator will run a test on that individual channel. Page 17 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 18: Nmea Screen

    The selected NMEA header will turn bold and the description of the NMEA being monitored is now displayed. The below example the $VDVBW sentence is selected. Page 18 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 19 NMEA data may also be filtered by typing the desired filter information into the “Filter” text box on the right of the screen. The streaming data will only show the data with the chosen characters. Page 19 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 20: Capsule Screen

    If after a few attempts then there may be a more serious issue requiring authorised attendance. The X2 system has three final storage devices – a Fixed Capsule, a Float Free Capsule and a 1TB SSD Long Term Recording Medium (LTRM) The fixed and float free capsules operate in the same manner as a network hard disc drive.
  • Page 21 Tapping the screen will open the “Disk Usage Information” display. User Control: Should either capsule show loss of connection, tapping the capsule icon will remap the capsule to resume correct operation Page 21 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 22: Power Screen

    If the Mains Power should fail the indication will turn YELLOW and the system will start a 2-hour countdown to switch OFF. Note that on the MEU, the red FAULT LED will illuminate. Page 22 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 23 Pressing the System Test will bring up a prompt ‘Press Again for System Test”. User Control: Pressing the System Test a second time will begin the full system test sequence. Page 23 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 24: System Test

    Tap the button and the System Test will pop up, tap again to initiate the System Test. The test function will be inhibited for 2 minutes. Page 24 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 25: Event Log Screen

    On this page you can review all events. You can select the search parameters by Date, Hour or Priority by selecting the relevant drop-down box. Page 25 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 26: Incident Marker

    An Event marker will be shown in RED. The event is saved in the Event Log file so that during download and playback the incident can be easily located. Page 26 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 27: Consumables Notifications

    Consumables Notifications Consumables Due If any of the consumables are due within 3 months the relevant box will turn YELLOW. Page 27 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 28: Consumables Over Due

    If any of the consumables have gone past their due date the Side indication bar will also flash YELLOW and the event will be added to the Log File. Page 28 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 29: System Maintenance Schedule

    6 Year Check The following must be conducted by an AMI authorised inspector/engineer. Annual Performance Test (APT) Replace MEU system fan Replace fixed capsule acoustic beacon. Page 29 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 30: Document Issue Details

    Rewording and formatting update NOTICE This manual is for informational use only. AMI Marine Limited continually strives to improve their products and therefor may be changed without prior notice. This manual should not be construed as a commitment of AMI Marine Limited. Under no circumstances does AMI Marine Limited assume any responsibility or liability for any errors or inaccuracies that may appear in this document.
  • Page 31 This page Intentionally Blank Page 31 of 33 08011 - X2 VDR and S-VDR System Operation Guide Iss01 Rev03...
  • Page 32: Warranty Form

    Crosshouse Road Southampton Hants SO14 5GZ A full explanation of AMI Marine Limited warranty conditions can be found on our web site or requested via email. * Terms of Service and Policies are subject to change without notice.  ------------------------------------------------------------------------------------------------------------------------------------------------------------------ Please complete and return to AMI Marine either by post to the above address or by email to technical@amimarine.com...