Core Insight AirStat 7110 User Manual

Pulsed ac ionization system

Advertisement

Quick Links

Ionizer User Manual
Model 7110
AirStat® Pulsed AC Ionization System

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AirStat 7110 and is the answer not in the manual?

Questions and answers

Summary of Contents for Core Insight AirStat 7110

  • Page 1 Ionizer User Manual Model 7110 AirStat® Pulsed AC Ionization System...
  • Page 2: Table Of Contents

    6. Drawings 7. Setup and Operation Introduction Contents in the box Descriptions for Model 7110 Installation Turning on the ionizer Parameter Settings Output Monitoring Setting 8. Maintenance Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
  • Page 3 9. Warranty and Services Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
  • Page 4: Core Insight Introduction

    Assessment, ESD Control Program, Product Qualification Testing per ANSI/ESD Standards, Device Testing and System Level ESD Testing per IEC 61000-4-2. Core Insight is major ESD distribution supplier in the field of semiconductor, flat panel display, automotive and electronic manufacturing working environment. Core founded in 2003...
  • Page 5: Ionization Technology

    & unwinding of films for static related contamination issues. Core Insight’s AirStat® Bipolar Pulsed AC ionizers which is lower frequency than conventional AC and output parameters are adjustable for each application such as FPD’s manufacturing environment and others.
  • Page 6: Pulsed Dc Ionization

    Core Insight offer several types of Charge Plate Monitor (CPM) or Test Kits for ionizer performance testing of qualification and compliance verification. Monroe Electronics’ Model 288 is the latest version of CPM and highly accurate measurement equipment based on the original voltage following technology.
  • Page 7 For more detail information about ionization and its test equipment, please feel free contact sales representative sales@coreinsight.co.kr or local contacts. Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
  • Page 8: Application Guide

    Association. Lowering device charge level and increase resistance of contact materials are the key strategical elements to prevent ESD damage. As per ANSI/ESD S20.20-2014 latest version described, maximum allowing Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
  • Page 9 CDM/CBE ESD failures in production or field return from customer side. Core Insight provides the best solution for static related issues with several types of ionization products and systems such as steady-state DC, AC, pulsed AC, high frequency AC and pulsed DC ionizations.
  • Page 10: Cautions And Personal Safety

    There are no user serviceable parts inside this ionizer. Any unauthorized service will void the warranty and may result Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
  • Page 11: Personal Safety

    ESD control method and remove power connection from AC line source. Be sure that no wrist strap requires when service access to high voltage operational system. Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
  • Page 12: General Specification

    124 H x 50 D x L (300, 400, 600, 800, 1000, 1200, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 2800, 3000) Option IR Remote Controller Warranty 1 year Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
  • Page 13: Drawings

    ESD issues in work environment. AirStat® Model 7110 Pulsed AC Ionizing Bar widely used in FPD manufacturing areas. For fine-tuning, output and Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
  • Page 14: Contents In The Box

    AirStat® Model 7110 Pulsed AC Ionizing Bar is designed enhanced self-power and controlled by itself without external. Contents in the box AirStat® Model 7110 Pulsed AC Ionizing Bar RJ45 Cable Remote Controller DC Adapter Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
  • Page 15: Descriptions For Model 7110

    LEDs: Operation indication and Alarm Function Button: Allow user to change parameters Next Button: Move next menu 10) UP: Change upper value 11) DOWN: Change lower value Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
  • Page 16: Installation

    After the wiring has been tested, connect the cable and apply power to the ionizer. Performed the adjustment procedure to determine the final settings and if necessary, adjust individual parameters. Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
  • Page 17: Turning On The Ionizer

    7110 Pulsed AC Ionizing Bar through FND display. User can select operation on/off, frequency, high voltage output levels by 0.1kV resolution, cleaning alarm settings, power alarm setting, synchronizing output and ID settings. Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
  • Page 18 Positive Voltage Adjust Negative Voltage Adjust Cleaning Alarm Low Current Set Cleaning Alarm Over Current Set HV Power Low Current Set HV Power Over Current Set ID Settings Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
  • Page 19 Press UP/DOWN to change value. 4) High Voltage Positive Output Adjust (Duty Cycle) Press FUN and press NEXT(5 ), Po.V will display. Press UP/DOWN to change value. Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
  • Page 20 7) ID Addressing Press FUN and press NEXT(10 ), Id.- will display. User can define ID address from 001 to 999. 8) Remote Controller Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
  • Page 21: Output Monitoring Setting

    Occasional cleaning of the case and emitter points is the only routine maintenance required. When user perform cleaning emitter points, CPM test required to make sure output of ionizers are fine. Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
  • Page 22 If using a swab, gently wipe the tips of the emitter points until the dirt is removed. After cleaning make sure that the emitter point need to dry out about 20 minute. Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
  • Page 23 Warranty and Service Core Insight, Inc. provides a limited warranty for all ionizers. New products manufactured or sold by Core are guaranteed to be free from defects in material or workmanship for a period of defined schedules from the date of initial shipment. Core’s liability under its...

Table of Contents