Download Print this page

Festo CPV14-VI-P Series Assembly Instructions page 2

Multiple connector plate

Advertisement

Available languages

Available languages

Assembly instructions (en)
746 709 / 2009-07a
Multiple connector plate
CPV14-VI-P...
1. Parts list
P2
P4
P6
9053d_13
9053d_16
9053d_11
2. Preparing for assembly
9053d_5 und 9053d_12
9053d_14
A _ 0.1
B _ 0.1
C _ 0.1
Type
CPV14-VI-P...-D 1
P2
42.6
30.5
55.6
P4
42.6
58.5
55.6
P6
42.6
86.5
55.6
P8
42.6
114.5
55.6
†‡
Festo SE & Co. KG
Postfach
D-73726 Esslingen
++49/(0)711/347-0
www.festo.com
1 Multiple connector plate
P8
1
CPV14-VI-P...-D
2 Multiple connector plate
CPV14-VI-P...-C
3 Seals
CPV14-VI-P.1/8
2
3
• Note the dimensions of
the cut-out for fitting
(! Table).
In order to comply with
protection class IP65:
• Make sure that the
surface near the sealing
surface:
– is flat.
– is free of marks and
scratches.
Mounting cut-out for
CPV14-VI-P...-D 1
D _ 0.1
N
12
4
40
6
68
6
96
6
9053d_16
A _ 0.1
B _ 0.1
C _ 0.1
Type
CPV14-VI-P...-C 2
P2
68
78
79
P4
68
106
79
P6
68
134
79
P8
68
162
79
3. Assembly
9053d_6
9053d_7
9053d_8
9053d_9
l – t = 7.5mm ... 9.5 mm
5 Nm _ 10%
9053d_10
9053d_17
Mounting cut-out for
CPV14-VI-P...-C 2
D _ 0.1
N
82
6
110
6
138
6
166
6
• Press the seals 3
supplied into the holes in
the CPV valve terminal.
• Note that the 3 and 4-part
3
seals supplied with the
end plates of the CPV
valve terminal are only
required with multiple
connector plate 2.
• Position multiple
connector plate 1 or 2
in the mounting cut-out
from inside.
1 / 2
• Fasten the multiple
connector plate 1 or 2
1 / 2
with corrosion resistant
N x M5 screws as per DIN
EN ISO 4762.
• Select the screw length l
as follows. A screw depth
of at least 7.5 mm to max.
9.5 mm must be
guaranteed.
• Tighten the screws.
Maintain the permitted
tightening torque.
For mounting the valve
terminal:
• Observe the assembly
instructions for the
pneumatic section of the
valve terminal.

Advertisement