schmalenberger FZ Series Operator's Manual & Installation Instructions

schmalenberger FZ Series Operator's Manual & Installation Instructions

Circulating pump
Table of Contents

Advertisement

Circulating pump
Typ Z, FZ, SZ, NZ, ZL, FZL, SZL, NZL,
ZB, FZB, SZB, NZB
Operator´s manual / installation instructions
GB
Translation of the original

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FZ Series and is the answer not in the manual?

Questions and answers

Summary of Contents for schmalenberger FZ Series

  • Page 1 Circulating pump Typ Z, FZ, SZ, NZ, ZL, FZL, SZL, NZL, ZB, FZB, SZB, NZB Operator´s manual / installation instructions Translation of the original...
  • Page 2 EU Declaration of Conformity Manufacturer: Schmalenberger GmbH + Co. KG Strömungstechnologie Im Schelmen 9-11 D-72072 Tübingen / Germany The manufacturer hereby declares that the product: Centrifugal pump type: Z, FZ, NZ, SZ, ZL, ZB, FZL, FZB, NZL, NZB, SZL, SZB, SZcut (identification numbers: all)
  • Page 3 EU Declaration of Incorporation Manufacturer: Schmalenberger GmbH + Co. KG Strömungstechnologie Im Schelmen 9-11 D-72072 Tübingen / Germany The manufacturer hereby declares that the product: Centrifugal pump if delivered without drive, type: ZB, ZL, FZB, FZL, NZB, NZL, SZB, SZL (identification numbers: all)
  • Page 4: Table Of Contents

    4.2.2 Miscellaneous ...................... 13 Indications of Faulty Operation ................13 4.3.1 General ........................ 13 4.3.2 Faults ........................13 Shutdown ......................14 Fault Elimination ....................15 Schmalenberger GmbH + Co. KG Pump Typ Z Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 5 FZL 5016, SZL 2513, SZL 3216, SZL 4013, SZL 5016, ZB, FZB 4013, FZB 5016, SZB 2513, SZB 3216, SZB 4013, SZB 5016 ............26 Type: NZ, FZ 6520, NZL, FZL 6520, NZB, FZB 6520 ......... 29 Pump Typ Z Schmalenberger GmbH + Co. KG Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 6: General Details

    • Drive operator’s manual or in the documentation for the relevant • Declaration of conformity with supple- design. ment BA for ATEX-pumps Schmalenberger GmbH + Co. KG Pump Typ Z Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 7: Technical Data / Specifications

    This sign warns you of the dan- trolled so that no danger occurs to per- ger of mechanical effects. sons or the environment. Comply with legal requirements. Pump Typ Z Schmalenberger GmbH + Co. KG Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 8: Temperature

    Schmalenberger GmbH + Co. KG Pump Typ Z Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 9: Conservation

    Observe the into the pump. instructions in section 3.1.1. Important: Before installation check that the pump runs freely and easily. Pump Typ Z Schmalenberger GmbH + Co. KG Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 10: Installing And Connecting

    The suction pipe to the pump must be installed to rise continuously, on the pressure side it must fall continuously. Schmalenberger GmbH + Co. KG Pump Typ Z Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 11: Electrical Connections

    2.0 mm and 0.5 mm wire diameter made of corrosion resistant material have proved useful in practice. Fig. 1 Connection for 3-phase motors, connection  Pump Typ Z Schmalenberger GmbH + Co. KG Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 12: Operating The Pump

    Once the maximum rotation speed has been reached, slowly open it up and adjust to full operational level. Schmalenberger GmbH + Co. KG Pump Typ Z Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 13: Operating

    1. Locate the site of the fault or defect. fluid. In order to prevent the motor being 2. Determine the cause. overloaded, density must 3. Remedy the fault. correspond to the specifications. Pump Typ Z Schmalenberger GmbH + Co. KG Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 14: Shutdown

    / or for occasions where it is to be at a standstill for longer periods of time, pump must emptied or protected against freezing auxiliary heating). Schmalenberger GmbH + Co. KG Pump Typ Z Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 15: Fault Elimination

    System resistances too low, manome- Increase back pressure, e.g. by thrott- ter defective ling the pump on the pressure side, larger pump (*), larger impeller (*) Pump Typ Z Schmalenberger GmbH + Co. KG Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 16 Gaskets defective, pump badly adju- Renew gaskets, adjust pump preci- sted, throttling section defective sely, check pipework connections, renew throttling section. (*) Please contact the manufacturer Schmalenberger GmbH + Co. KG Pump Typ Z Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 17: Maintenance / Repair

    Bearings larger motors must relubricated on a regular basis. See also the "Operator's Manual for Pump Drives" in section 6.2 "Motor Bearings". Pump Typ Z Schmalenberger GmbH + Co. KG Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 18: Repair

    Important: For the following work, please be sure to observe local regulations and conditions. Schmalenberger GmbH + Co. KG Pump Typ Z Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 19: Dismantling / Dismantling The Pump

    164. When re-assembling install new gaskets and a new wearing plate. Pump Typ Z Schmalenberger GmbH + Co. KG Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 20: Dismantling The Pump Type Nz, Fz 6520

    24 hours before assembly When re-assembling install new can proceed. See assembly instructi- gaskets. ons (AA-18003). Make sure that this period of time is observed! Schmalenberger GmbH + Co. KG Pump Typ Z Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 21: Bearing Support

    Replace defective parts! Assemble the parts in reverse order. To change the coupling or a bearing, proceed as follows: Pump Typ Z Schmalenberger GmbH + Co. KG Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 22: Appendix

    The cleaning agents and rests must be removed. Proceed as described in of the delivery medium must chapter 3.2.2. also be handled in accordance with legal requirements. Schmalenberger GmbH + Co. KG Pump Typ Z Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 23: Documentation For Pump Operation

    1. If you send the pump back to the manufacturer for repair or an upgrade then please be sure to enclose precise details of the media that were delivered by the pump. Pump Typ Z Schmalenberger GmbH + Co. KG Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 24 Schmalenberger GmbH + Co. KG Pump Typ Z Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 25 Pump Typ Z Schmalenberger GmbH + Co. KG Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 26: Fzl 5016, Szl 2513, Szl 3216, Szl 4013, Szl 5016, Zb, Fzb 4013, Fzb 5016, Szb 2513, Szb 3216, Szb 4013, Szb 5016

    Distance washer 554.02 Distance washer 554.03 Distance washer Protective plate Protective plate for 331 Pressure pipe Suction pipe extension Angle (pipe bend 90°) Transition piece Schmalenberger GmbH + Co. KG Pump Typ Z Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 27 Hexagon nut for 901.04 Impeller nut Retaining ring 932.01 Retaining ring Fitting key 940.02 Fitting key Not all parts are built into every pump, however. Pump Typ Z Schmalenberger GmbH + Co. KG Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 28 Schmalenberger GmbH + Co. KG Pump Typ Z Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 29: Type: Nz, Fz 6520, Nzl, Fzl 6520, Nzb, Fzb 6520

    Protective plate Protective plate for 331 Pipework Pressure pipe Transition piece Pipe connection Angle (pipe bend 90°) IEC Norm motor, for Type Z-L / Z-B Pump Typ Z Schmalenberger GmbH + Co. KG Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 30 Plug screw Threaded rod Ventilation screw Cylinder head screw withhexagon socket Impeller nut Retaining ring Fitting key Not all parts are built into every pump, however. Schmalenberger GmbH + Co. KG Pump Typ Z Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 31 Pump Typ Z Schmalenberger GmbH + Co. KG Version: 27215 -G.1 D-72072 Tübingen / Germany...
  • Page 32 +49 (0)7071 70 08 - 14 Im Schelmen 9 - 11 Internet: www.schmalenberger.de D-72072 Tübingen / Germany E-mail: info@schmalenberger.de © 2019 Schmalenberger GmbH + Co. KG ; All Rights reserved This document is subject to change without notice Pump Typ Z Version: 27215 -G.1...

Table of Contents