INSTRUCTION MANUAL Skin and Vein Replacement LF01274 Light, LF01275 Medium LF01276 Dark, LF01277 Veins WARNING: Products may contain dry natural rubber. Do not remove film from tubing.
List of Components LIST OF COMPONENTS FOR LF01274 • 2-oz. bottle of Baby powder • 2-oz bottle of lubricant • Replacement Skin, Light LIST OF COMPONENTS FOR LF01275 • 2-oz. bottle of Baby powder • 2-oz bottle of lubricant • Replacement Skin, Medium LIST OF COMPONENTS FOR LF01276 •...
Page 4
Removing the Arm Skin & Veins Figure 2 A. To remove the skin from the arm core, bend the skin flap around top of arm. Remove the inlet and outlet tubes from the arm skin. Note: If you are replacing the skin and the veins, simply cut the skin free from the arm core using scissors and discard.
Page 5
Replacing the Vein Tubing A. Figure 3 shows how the four vein tubing sections should be connected to the connector block. The tube fittings are not shown. Note: All diagrams have been color coded for illustrationpurposes only. The latex veins you received with your kit are different configuration and length.
Page 6
Figure 5 C. Refer to Figure 5 (Green). Plug one end of a uniform diameter tubing piece into fitting #2. Press the tubing into the channel, around the loop near the wrist, and back to the connector block at fitting #3, trimming excess.
Page 7
Figure 7 E. Refer to Figure 7 (Blue). Plug one end of a uniform diameter tubing piece into fitting #6. Tuck it under the “green” tubing, then continue to press it into the channel, taking extra care to minimize pinching in the loops around the two fingers and the back of the hand.
Page 8
Reassembling the Arm Figure 8 Figure 9 Figure 10 A. Feed the inlet/outlet tube through the large channel and out the hole in the upper arm. Replace the muscle pad over it. Shake baby powder into the inside of the arm (see Figure 8). Pinch the end of the arm skin closed and shake the arm to distribute the powder inside the skin.
Page 9
Figure 11 Feel along the tubing channel to make sure that the tubing is correctly seated. Tubing that has moved can usually be moved back into position by working on the outside of the skin. (See figure 11.) Figure 12 Figure 13 G.
Supplies & Replacement Parts LF00845U Blood, 1 quart Life/form ® LF00846U Blood, 1 gallon Life/form ® LF00991U Shoulder Injection Pad Replacement LF00993U Replacement Vein Manifold LF00985U Lubricant, pack of 6, 2-oz. bottles LF01279U Skin Sealant LF01022U Fluid Supply Stand LF01099U Vein Tubing Sealant LF01104U IV Arm Skin &...
Page 11
Other Available Simulators LF00698U Adult Injectable Arm (Light) LF03617U Deluxe Child CRiSis™ LF00958U Pediatric Injectable Arm Manikin with Arrhythmia LF00961U Intramuscular Injection Tutor LF00995U Arterial Puncture Arm LF03620U PALS Update Kit LF00999U Pediatric Injectable Head LF03632U Child Intraosseous Infusion/ LF01005U First Aid Arm Femoral Access Leg on a LF01007U...