DAB E.Box Plus Instruction For Installation And Maintenance page 114

Hide thumbs Also See for E.Box Plus:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 64
HA: Pumps stopping level (only in drainage or filling with depth sensor)
Stopping level of pumps P1 and P2.
9.4.4 INSTALLER MENU
From the main menu, hold down simultaneously the "MODE" and "SET" keys until "INSTALLER MENU" appears on
the display (or use the selection menu pressing "+" or "-"). The menu allows you to view and modify various
configuration parameters: the MODE key allows you to scroll through the menu pages, the "+" and "-" keys allow you
respectively to increase and decrease the value of the parameter concerned. Press SET to leave this menu and return
to the main menu.
Also in this menu, different parameters may be seen depending on the operating mode.
RC: Setting the rated current of the electropump
Rated current absorbed by the pumps in Ampere (A). The rated current of the pumps used must be set. The rated
current refers to the type of connection used, star or delta or single-phase. If 2 pumps are used, they must be
identical.
MF: Operating mode
This parameter expresses the operating mode of the E.Box. KIWA pressure boosting mode is available only if the
language selected is Dutch, French or English. If the operating mode is changed, the wizard starts automatically with
the request for the parameters that have not been configured.
MC: Control devices
This parameter allows you to choose the type of inputs that inform the E.Box about the system status. The inputs may
be floats, level probes, pressure sensors or depth sensors, depending on the type of application.
GS: Protection devices (only in drainage or filling or with depth sensor)
This parameter allows you to choose the type of inputs that inform the E.Box about anomalous conditions of the
system. The inputs may be floats, level probes or the depth sensor.
PR: Type of sensor used (only if a pressure or depth sensor is used)
This parameter allows you to choose the type of sensor connected to the E.Box.
MS: Measuring system
This parameter allows you to choose the type of measuring system used to express the values on the display. The
values may be expressed with the metric system or with the imperial system.
SO: Dry running factor
Sets a minimum threshold of the dry running factor below which the lack of water is detected. The dry running factor is
a non-dimensional parameter obtained from the combination of the absorbed current and the power factor of the
pump. Thanks to this parameter it can be correctly established when a pump has air in the impeller or when the intake
flow is interrupted.
If you want to use this type of protection against dry running, the parameter TB (block time for lack of water) must be
set at a value other than zero.
To set the SO threshold, it is recommended to perform the following tests (with parameter TB at 0):
run the pump at a low flow rate and memorise the SO value read
run the pump dry.
Set TB at the desired value and set SO halfway between the 2 values read in the 2 previous situations.
MP: Minimum pressure threshold (only in pressure boosting and KIWA pressure boosting)
Sets a minimum pressure for switching off due to water lack. If the pressure in the plant arrives at a pressure below
the MP, the water lack signal is given. This too requires a TB value other than 0 to be active.
OD: Expansion vessel size (only in pressure boosting and KIWA pressure boosting)
Allows you to set the size of the expansion vessel.
EP: Pump exclusion
Allows you to exclude one or both pumps; useful if only one pump is connected to the E.Box panel.
ENGLISH
112

Advertisement

Table of Contents
loading

This manual is also suitable for:

E.box plus dE.box basicE.box basic d

Table of Contents