OneControl Touch Panel or OneControl App Error Codes
NOTE: Faults can only be cleared via the OneControl Touch Panel or OneControl App. The only exception is
when the Auto Leveling Control Touch Pad (Fig. 1) was used to abort an auto-sequence. In this case
the fault can be cleared by pressing any Auto Leveling Control Touch Pad button.
OneControl Touch Panel or OneControl App Error Codes
NOTE: Faults can be cleared via the OneControl Touch Panel, OneControl App or Auto Leveling Control
Touch Pad. Most standard faults can be cleared from the Auto Leveling Control Touch Pad by
pressing "Retract All."
Touch Panel
Message
"EXCESS ANGLE"
"EXCESSIVE ANGLE"
"BAD CALIBRATION"
"FEATURE DISABLED"
"LOW VOLTAGE"
"OUT OF STROKE"
"EXTERNAL SENSOR"
"JACK TIME OUT"
"AUTO LEVEL FAIL"
"FUNCTION ABORTED"
"HALL POWER SHORT"
7 2
Rev: 06.28.18
OneControl Touch Panel or OneControl App Error Codes
What's Happening?
Unsecured controller.
Uneven or sloped site.
Excessive angle reached during
manual operation.
Trailer zero point was not set
correctly.
Hitch recognition requested but no
hitch height set.
Zero point not set.
Bad connection or wiring.
Discharged or bad battery.
Unsecured controller.
Uneven or sloped site.
Bad connection or wiring.
System could not level in expected
time.
Unsecured controller.
Voltage drop.
User has aborted an automatic
leveling sequence.
Short circuit detected on one or
more of the jack hall effect power
lines.
Page 14
(Rev. A)
(Rev. B)
What Should I Do?
Check and secure controller placement.
Relocate the trailer.
Stop manual operation and reset jacks to
a more level state. The code will self clear.
There is no need to hit "OK."
Reset zero point.
Perform "AUTO LEVEL" sequence to
establish hitch height.
Set zero point.
Check wiring - repair or replace.
Test battery voltage under load - charge or
replace.
Check and secure controller placement.
Relocate the trailer.
Replace or repair connection to rear remote
sensor.
Check disposition of jacks.
Check and secure controller placement.
Test battery voltage under load - charge or
replace.
Hit OK. Restart the sequence.
Check harness and replace or repair.