6.2

/R-Output

OSSD safety outputs
switching voltage/switching current
OSSD external fusing (EN 60269-1)
Contact currents (IEC EN 60947-5-1)
OSSD response time MSI
(without AOPD)
OSSD reset time
OSSD suitable spark extinguishing
over the coils of the downstream relays
Status output "Status switch outputs" not to be used for
safety circuit!
Status output
"Status start/restart interlock"
2 safety-related normal open contacts,
60 V DC, 250 V AC, 5 A max.
Minimum switching current 20 mA
4A gG D-fuse
AC15, 3A
DC13, 2A
for AOPD Type 4, transistor outputs
for AOPD Type 4, relay outputs
for AOPD Type 2
for safety switches (electro mechani-
cal)
100 ms
Required
pnp switch output
OSSDs ON-state:
OSSDs OFF-state:
pnp switch output
locked:
not locked:
MSI-s
22 ms
64 ms
64 ms
64 ms
active high, 24 V DC, 60 mA max.
active low
active high, 24 V DC,, 60 mA max.
active low