Check Parts Unit - Pioneer YH024GHFI18RT2 Technical & Service Manual

High efficiency condensing unit, r-410a refrigerant 208-230 v, 1 phase, 60 hz 18 seer
Hide thumbs Also See for YH024GHFI18RT2:
Table of Contents

Advertisement

15. CHECKING COMPONENTS

15.2 Check parts unit

1. Outdoor unit fan motor
DC motor
24K: ZWK511A805001
36K/60K: SIC-71FW-F8121-1
2. Compressor
Compressor examination and repairing
24K/ 36K : EATF250D22UMT
60K: EATF400D64UMTA
Power
Test in resistance.
TOOL: Multi-meter.
Test the resistance of the winding. The compressor fails if the resistance of winding is 0
(short circuit)or∞(open circuit).
Familiar error:
1) Compressor motor lock.
2) Discharge pressure value approaches static pressure value.
3) Compressor motor winding abnormality.
DC Inverter
&
Controller
62
Thermal Sensor
Compressor

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yh036ghfi18rt2Yh060ghfi18rt2

Table of Contents