15. CHECKING COMPONENTS
15. Checking components
15.1 Check refrigerant system
TEST SYSTEM FLOW
Conditions: ① Compressor is running.
② The air condition should be installed in good ventilation.
Tool: Pressure Gauge
Technique: ① see ② feel ③ test
See ----- Tube defrost.
Feel ----- The difference between the temperature of tubes.
Test ----- Test pressure.