Download Print this page
Onset InTemp CX5000 Manual

Onset InTemp CX5000 Manual

Advertisement

Quick Links

InTemp® CX5000 Gateway Manual
InTemp CX5000
Gateway
Included Items:
• Mounting kit
• AC adapter
Required Items:
• InTempConnect
account
• InTemp app
• Device with iOS or
Android™ and
Bluetooth
• CX series loggers
Setting up the Gateway
Follow these instructions for setting up the gateway in your
current location. If you are an IT administrator configuring the
gateway for use at a different location, see Setting up the
Gateway at a Different Site.
1. Set up roles on the InTempConnect website for
gateway privileges.
a. Go to www.intempconnect.com and follow the prompts
to set up an administrator account or skip to the next
step if you already have an account.
b. Log into the account at www.intempconnect.com.
c. If you are an administrator or created the account and
will be setting up the gateway, you can skip to step 2
because you automatically have the required privileges.
Otherwise, you must create a role or edit an existing
role to add the privileges. Click Settings and then Roles.
d. Click Add Role and enter a description or select an
existing role. Note: You must be an InTempConnect
administrator or a user with Manage Users and Roles
privileges.
e. Select the Gateway privileges from the Available
Privileges list on the left and click the right arrow button
to move them to the Assigned Privileges list on the right
as shown in this example.
21781-I
The InTemp CX5000 Gateway is a device that uses Bluetooth® Low Energy (BLE) to regularly
configure and download up to 50 CX series loggers and upload the data to the InTempConnect®
website automatically via Ethernet or WiFi. The gateway requires an InTempConnect website
account with gateway privileges and a phone or tablet with the InTemp app to set up the
gateway.
Specifications
Transmission Range
Approximately 30.5 m (100 ft) line-of-sight
Wireless Data Standard
Bluetooth 4.2 (BLE)
Connectivity
WiFi 802.11a/b/g/n 2.4/5 GHz or 10/100 Ethernet
Power Source
AC adapter
Dimensions
12.4 x 12.4 x 2.87 cm (4.88 x 4.88 x 1.13 inches)
Weight
137 g (4.83 oz)
The CE Marking identifies this product as complying with all relevant
directives in the European Union (EU).
Gateway
Description
Privilege
Manage Logger/
Set up or edit a gateway profile in
Gateway Profiles
InTempConnect.
Manage
Monitor active gateways in
Gateways
InTempConnect and configure loggers
with the gateway.
Create
Set up shipments of loggers via the
Shipments
gateway.
Edit/Delete
Change or delete planned shipments of
Shipments
loggers via the gateway
Gateway
Set up and configure a gateway with
Administrator
the InTemp app.
Select any other privileges you want the user to have
(privileges for the InTempConnect website are noted
with a cloud
icon and privileges for the InTemp app
are noted with a mobile device
f. Select a user for this role and click Save. Or, if you need
to add a user, click Save and then click Settings > Users.
Click Add User and enter the email address and first and
last name of the user. Select the role with the gateway
privileges for the user and click Save.
Tip: You can assign these roles to the same user or different
users.
2. Set up a gateway profile.
a. In the InTempConnect website, click Gateways and
then Gateway Profiles.
b. Click Add Gateway Profile.
c. Type a name for the gateway, up to 30 characters.
d. Select the logger family that will be used with the
gateway (you can select more than one).
icon).

Advertisement

loading

Summary of Contents for Onset InTemp CX5000

  • Page 1 InTemp® CX5000 Gateway Manual The InTemp CX5000 Gateway is a device that uses Bluetooth® Low Energy (BLE) to regularly configure and download up to 50 CX series loggers and upload the data to the InTempConnect® website automatically via Ethernet or WiFi. The gateway requires an InTempConnect website account with gateway privileges and a phone or tablet with the InTemp app to set up the gateway.
  • Page 2: Power Up The Gateway

    InTemp CX5000 Gateway Manual e. Select what you want the gateway to do with each 5. Power up the gateway. logger when connected: Download and Restart, a. Insert the appropriate plug for your region into the AC Download and Continue, or Download and Stop.
  • Page 3: Configure The Gateway

    InTemp CX5000 Gateway Manual address. Repeat if necessary (the app can store up to profile. Data will be uploaded to the InTempConnect website, three DNS server addresses). Tap Save. where you can configure loggers, create shipments, search logger configurations, run reports, or schedule regular delivery...
  • Page 4 InTemp CX5000 Gateway Manual Once the gateway mounting plate is in place on the wall or current configuration in the list for the status, last upload other flat surface, use the four holes on the back of the date/time and last contact with InTempConnect.
  • Page 5 InTemp CX5000 Gateway Manual connection can download the logger instead, thereby 8. Select the "Release on import" checkbox if you want the expanding the coverage area and reducing the risk of multiple gateway to configure the loggers in the file as soon as the gateways incorrectly affecting a logger.
  • Page 6 © 2017–2020 Onset Computer Corporation. All rights reserved. Onset, InTemp, and InTempConnect are registered trademarks of Onset Computer Corporation. App Store is a service mark of Apple Inc. Android and Google Play are trademarks or registered 1-800-LOGGERS (564-4377) • 508-759-9500 trademarks of Google Inc.