9.4 Module testing recommendations

When testing your integration design:
Test to your worst case operating environment conditions (temperature and
voltage)
Test using worst case operation (transmitter on 100% duty cycle, maximum
power)
Monitor temperature at the location shown below—this should be the hottest
spot on the device (the WCDMA PA).
Figure 9-1: Recommended thermocouple location
Note: Make sure that your system design provides sufficient cooling for the module. The
RF shield temperature should be kept below 90
the module's components.