GIRA
Smoke detector
Info
Instructions for Installation
Operating and alarm signals
Signal sound
Loud intermittent sound
Loud intermittent sound
Short signal sound at 45 sec.
intervals
Short signal sound at 45 sec.
intervals
—
Loud intermittent sound
Function test
Caution:
The smoke detector produces a very loud and shrill sound, which can damage hearing. For this
reason, please observe a safety distance of 50 cm during the function test.
Carry out the function test on a monthly basis. To do this, proceed as follows:
1. Press the test buttons:
If the audible signal sounds, the smoke detector is working correctly.
If no audible signal sounds, please replace the battery with a new one.
2. Then, carry out the function test again.
If the audible signal still does not sound, the smoke detector is defective and must replaced with a
new unit.
For linked smoke detectors, all connected smoke detectors must produce an acoustic alarm during the
function test. If this does not occur, please check the following things: battery dead, cable correctly
connected, cable defective!
Maintenance and care
In order to ensure the proper function of the smoke detector for a long period, you should carry out
maintenance approx. biannually (or in case of a disturbance notice). To do this, proceed as follows:
1. Remove the smoke detector from the socket (turn counter- clockwise) and remove dust.
2. Wipe the smoke detector off with a moist towel.
3. Stick the smoke detector into the socket again and turn it clockwise until it locks into place.
Caution: If no battery if present, the smoke detector cannot be locked in the socket.
4. Check whether the automatic self-test (smoke detector blinks every 45 seconds) is carried out.
5. Carry out a function test.
Exchange all smoke detectors after about 10 years.
Smoke detector
Signal
Light diode
Blinks
—
Blinks alternately to the signal
sound
Blinks parallel to the signal
sound
Blinks at 45 sec. intervals
Blinks
45/00
Meaning
Local smoke alarm
Smoke alarm to linked smoke
detector
Disturbance/soiling
Battery change display
Automatic self-test, normal
operating condition
Function test, trigger by test
button
Seite: 4 von 5