4-16
Chapter 4 - Maintenance and Troubleshooting

Event Trace Mode

The T command enables and disables the STSe System Trace mode. While the trace mode is
enabled events for the trace desired displays on the monitor, printer or PC connected to the
STSe system. To view the current status of the trace mode type [t] and press <Return> at the
mon> prompt, the following screen displays:
mon>t
Cmd
---
B - BOARD EVT
C - COL States -> N
D - Dev PP Cmd -> N
E - Error Msg
H - H/W States -> N
I - CTI PP Msg -> Y
K - LCD PP Cmd -> N
L - LED PP Cmd -> N
M - MSC States -> N
P - PCM
Q - Que Evt
S - Stn States -> N
mon>
1. To enable an Event Trace, type t<space> (space bar).
2. Indicate type of trace desired [d], where d is determined as follows:
B
M
P
C
S
E
Q
D
3. Enter the specific board, CO line or Station number of the trace desired, or type all when
all boards, CO lines or Stations events are desired.
001-028 = CO Line port
100-149= Station location
All = All Boards, CO lines or Stations
STARPLUS STSe - Installation Manual
Messages
Y/N
--------
---
-> N
-> N
-> N
-> Y
Trace ALL
Figure 4-6: Trace Mode Status
Board event trace (traces events associated with PCB)
Miscellaneous State event trace
Pulse Coded Modulation (PCM) traces events associated with voice
communications
CO Line (LCOB) States (traces events associated with CO Line activity)
Station (STA) States (traces events associated with Station activity)
Error Messages (traces error messages)
Queue (QUE) Events (traces queuing events: DTMF receiver, UCD, LCR, etc.)
D = Device Command (traces commands to peripheral devices)
Remote System Monitor
August 2005