Faber CRISTAL HC Instructions Manual

Slideout rangehood
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD
WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium setting. b)
ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED MUST BE SEALED.
This rangehood requires at least 24" of clearance between the bottom of the rangehood and the cooking surface or countertop.
This minimum clearance may be higher depending on local building code. For example, for gas ranges, a minimum of 30" may
be required. Overhead cabinets on both sides of this unit must be a minimum of 18" above the cooking surface or countertop.
Consult the cooktop or range installation instructions given by the manufacturer before making any cutouts. MOBILE HOME
INSTALLATION The installation of this rangehood must conform to the Manufactured Home Construction and Safety Standards,
Title 24 CFR, Part 3280 (formerly Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280). Four wire
power supply must be used and the appliance wiring must be revised. See Electrical Requirements.
un élément de la table de cuisson fonctionner sans surveillance à la puissance de chauffage maximale; un renversement/
TOUTE OUVERTURE DANS LE MUR OU LE PLANCHER À PROXIMITÉ DE LA HOTTE DOIT ÊTRE SCELLÉ
Gardez 24 po. de hauteur entre le bas de la hotte et la surface de cuisson. Cette hauteur minimum peut être plus haute suivant le
code municipal. Par exemple, les cuisinières à gaz peuvent requérir 30 po. de hauteur. Les armoires au-dessus de chaque côté
L'installation de cette hotte doit être conforme aux Réglements de Manufactured Home Construction and Safety Standards, titre 24
CFR, Section 3280 (anciennement Federal Standard for Mobile Home Construction and Safety Standards, titre 24 CFR, Section
3280 (anciennement Federal Standard for Mobile Home Construction and Safety, titre 24, HUD, Section 280). Le branchement
CRISTAL HC
Slideout Rangehood
The Installer must leave these instructions with the homeowner.
The homeowner must keep these instructions for future reference
and for local electrical inspectors' use.
-
Version 09/12 - Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CRISTAL HC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Faber CRISTAL HC

  • Page 1 CRISTAL HC Slideout Rangehood The Installer must leave these instructions with the homeowner. The homeowner must keep these instructions for future reference and for local electrical inspectors' use. READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings.
  • Page 2 This appliance should be connected directly to the fused Determine which venting method is best for your application. nonmetallic sheathed copper cable. Allow some slack in the Ductwork can extend either through the wall or the roof. cable so the appliance can be moved if servicing is ever nec- essary.
  • Page 3 qu'un contact d'un demi-pouce (1/2 po.) soit installé à chaque Faites un trou de 1 1/4 po. dans le mur. S'il s'agit d'un trou en le toit. bois - sablez-le bien, tandis qu'un trou passant par le métal demande un bouche-trou. Utilisez une longueur de tuyauterie minimale avec les moindres tuyauterie doit être uniforme.
  • Page 4 FRONT TRIM OPTIONS The Cristal HC comes with a white front strip installed. Optional black and brushed aluminum strips are included in the box. For a custom front strip, a local cabinet shop can make a strip to match your cabinets.
  • Page 5: Plan The Ductwork

    FIGURES 1 and 2 show vertical and horizontal installations for this unit. shows recirculating installation. The Cristal HC requires 6" round ductwork. To ensure that the blower performs to its highest possible capacity, ductwork should be as short and straight as possilbe.
  • Page 6: Prepare The Cabinet

    PREPARE THE CABINET The rangehood mounts to the cabinet by two spring loaded brackets, one on each side of the rangehood . Lift Disconnect and move freestanding range from cabinet the rangehood into the cutout opening in the cabinet. Be careful opening to provide easier access to upper cabinet and rear wall.
  • Page 7 FRONT TRIM OPTIONS The Cristal HC comes with a white front strip installed. Optional black and brushed aluminum strips are included in the box. To change the front strip, remove the three phillips screws located behind the strip . If necessary, the front strip can be adjusted by loosening the three phillips screws and sliding the strip up or down.
  • Page 8 WIRING DIAGRAM / DIAGRAMME DE FILAGE 177 035 NewCristal Version 09/12 - Page 8...
  • Page 9 To obtain warranty service, contact the dealer from whom you purchased the rangehood, or the local Faber distributor. If you cannot identify a local Faber distributor, contact us at (508) 358-5353 for the name of a distributor in your area.
  • Page 10 3 3/8” OPTIONS DE LA BANDE FRONTALE La bande frontale instaleé sur la Cristal HC est blanche. Une bande noire et une bande aluminum brossé sont incluses une bande qui s’assortira aux armoires. LES DIMENSIONS DE LA BANDE SUR MESURE...
  • Page 11 La hotte arrives avec conduit vertical. Les FIGURES 1 et 2 montrent l’installation avec conduit vertical et horizontal. La hotte Cristal HC requiert le conduit rond de 6 po. Pour assurer que le ventilateur marche le mieux, le conduit doit être aussi court et aussi droit que possible.
  • Page 12: Installation De La Hotte

    CUT-OUT FIGURE 5 INSTALLATION DE LA HOTTE Une bande est incorporee dans l' emballage Retirer l’appareil de la boîte et le déposer sur une surface plate pour l’assemblage. Couvrir la surface pour éviter tout vis . dommage. Retirer toutes les pièces incluant les le registre à clapet, la grille en plastique, et nécessaire de documentation l’appareil et mettre de côté.
  • Page 13: Utilisation Et Entretien

    OPTIONS DE LA BANDE FRONTALE La bande frontale instaleé sur la Cristal HC est blanche. Une bande noire et une bande aluminum brossé sont incluses dans bande frontale, dévisser les trois vis en retrait situées derrière la bande frontale . Si nécessaire, la bande frontale peut être ajustée en désserrant les trois vis en retrait et en la...
  • Page 14 à partir de la date d’achat. La garantie couvre marchand où la hotte a été achetée ou le distributeur Faber de la région. Si l’on ne peut trouver de distributeur Les frais suivants ne sont pas couverts par la garantie Faber : Les appels de service pour corriger l’installation de votre hotte de cuisinière, pour vous indiquer...

Table of Contents