PACKAGING & TRANSPORT
JRZS series are shipped in non-returnable wooden packaging.
Unpack the pump/unit upon delivery and inspect it for visible transport damage.
Any damage occurred during the transporting has to be immediately reported to the transport agent
after receipt of the consignment. Do not put the damaged products into operation.
The pumps need to be transported and secured with care to ensure no damage caused. Lifting
equipment (hoist) and load securing straps must be placed with sufficient load capacity.
Make sure you sent the pump down on a sufficient table, horizontal surface.
Below picture of complete unit with drive & common bed is shown for the example.
Caution)
*Do lift after dismantling the motor cover.
*Do keep alignment between pump's and motor's shafts.
*Do not lift the pump by the screw case, gearbox or integral adaptor.

STORAGE

If the pumps need to be stored temporarily, it should be sufficiently preserved under normal
environmental conditions and must not be exposed to the weather for any significant period of time.
Heed below measures when required to be stored longer period.
1. Protect pumps with dust, dirt, water or any other harmful environmental factors. Coat all
non-painted surfaces with acid-free and resin-free grease.
2. Do not grease stainless steel parts and non-metallic parts.
3. Cover all openings of pressure and suction ports.
4. Drain water when using it as flushing/quench medium for shaft seal.
5