Download Print this page
PISCO SVA20 Series Manual

PISCO SVA20 Series Manual

Push-in fitting incorporated type manifold solenoid valve

Advertisement

Quick Links

Push-In Fitting Incorporated Type Manifold Solenoid Valve
Solenoid Valve
Effective Sectional Area 18mm
SVA20 Series
Lightweight and Large Capacity
with valve width 16mm (5/8" )
2
(Cv 0.97)
Various Valve Selections
pisco.com
pisco
http://www.
http:/
/www.

Advertisement

loading

Summary of Contents for PISCO SVA20 Series

  • Page 1 /www. Push-In Fitting Incorporated Type Manifold Solenoid Valve SVA20 Series Solenoid Valve Lightweight and Large Capacity ● Effective Sectional Area 18mm ● (Cv 0.97) with valve width 16mm (5/8" ) Various Valve Selections ●...
  • Page 2 SOLENOID VALVE Series SVA20 Series Solenoid Valve ■ Characteristics Easy maintenance by a single-screw mechanism. ● 3 selections of wiring; Sub-D, Flat (Ribbon) Cable and Individual Plug-in ● Connector 2 selections of connector lead-out direction: (Top and Side)  ●  ●...
  • Page 3 /www. ■ Construction ● 2-Position, 5-Port, Single Solenoid Valve (SVA □ S) Part Material ⑧ ⑨ ⑬ ⑦ ③ ⑩ Fitting Ass'y ② ① Manifold-block Polyamide Base Plastic Pilot Valve Ass'y Electric Component Ass'y 4(A) Valve Body...
  • Page 4 SOLENOID VALVE Series SVA20 Series Solenoid Valve ● 2 Position, 3-Port, Solenoid Valve (Twin 3-Way Valve) A / B Port: Normally Closed (SVA□E) A / B Port: Normally Open (SVA□F) 4(A) 4(A) 1(P) 1(P) 2(B) 2(B) A Port: Normally Closed, B Port: Normally Open...
  • Page 5 /www. ● Vacuum-Operable 2/3 Port Solenoid Valve 2-Position, 2-Port, Single Solenoid Valve (SVA□T) 2-Position, 2-Port, Double Solenoid Valve (SVA□U) 1(B) 2(A) 1(B) 2(A) 2-Position, 3-Port Single Solenoid Valve (SVA□V) 2-Position,3-Port, Double Solenoid Valve (SVA□W) 3(R) 3(R)
  • Page 6 SOLENOID VALVE Series SVA20 Series Solenoid Valve ■ Model Designation of SVA20 Manifold Type(Example) 1/4C 3/8L Resin Solenoid Valve 20 Series (Valve width: 5/8" (16mm) ) ① Number of Stations ② Intake & Exhaust Block ③ Output Port Size ④...
  • Page 7 ⑬ Common Input ⑫ DIN Rail Mounting Bracket ⑪ Dual Pressure Option ⑩ ⑩ Valve Coil Voltage ⑨ Valve Type ⑧ Color ⑦ Wiring Type ⑦ Wiring Type D: Sub-D Connector S: Individual Plug-in Connector F: Flat (Ribbon) Cable Connector ⑧...
  • Page 8 SVA20 Series Solenoid Valve ■ Model Designation of Mounting Unit (Example) ⑤ Resin Solenoid Valve ④ Common Input Color ③ 20 Series (Valve width: 5/8" (16mm)) Wiring Type ① ② ② Valve Type Valve Coil Voltage ① Valve Type Code Position No. of Port Valve Type Code Position No.
  • Page 9 /www. ■ Code Example Model Series Number of Intake /Exh. Output Intake Exhaust Exhaust Wiring Color Valve Coil Dual Pressure DIN Rail Common Stations Port Size Port Size Check Valve Port Size Type Type Voltage Option Bracket Block config.
  • Page 10 SOLENOID VALVE Series SVA20 Series Solenoid Valve Order Form: SVA 20 Series To: PISCO USA, Inc. From : Name : Order Date : Requested EX-W PISCO Date : Quantity : Model Series Number of Intake /Exh. Output Intake Exhaust Exhaust Wiring...
  • Page 11 /www. ■ Manifold Specification Model SVA 20…A-…-D SVA 20…B-…-D SVA 20…A-…-F SVA 20…B-…-F SVA 20…A-…-S SVA 20…B-…-S Item Fluid Medium Operating Pressure Range 30~100psi (0.2 ~ 0.7MPa) Pressure Resistance 150psi (1.05MPa) Operating Temp. Range ( 5 ~ 50ºC) 40 ~ 120°...
  • Page 12 SOLENOID VALVE Series SVA20 Series Solenoid Valve ■ Solenoid Valve Specifications (AC100V) Model SVA 20S-100 SVA 20D-100 SVA 20A-100 SVA 20E-100 SVA 20T-100 SVA 20U-100 SVA 20V-100 SVA 20W-100 SVA 20R-100 SVA 20F-100 SVA 20P-100 SVA 20G-100 Item SVA 20H-100...
  • Page 13 /www. ■ Flow Characteristics SVA 20S- □ SVA 20D- □ SVA 20A-□ Model SVA 20E-□ SVA 20T-□ SVA 20V-□ SVA 20R-□ SVA 20F-□ SVA 20U-□ SVA 20W-□ SVA 20P-□ SVA 20G-□ Piping Port SVA 20H-□ C (*3) 1(P) →...
  • Page 14 SOLENOID VALVE Series SVA20 Series Solenoid Valve ■ Electric Circuit (DC24V) ●Sub-D connector 25 pins 9 pins A side coil A side coil st 1 st 1 B side coil B side coil A side coil A side coil st 2...
  • Page 15 /www. ■ Electric Circuit (AC100V) ●Sub-D connector 25 pins 9 pins A side coil A side coil st 1 st 1 B side coil B side coil A side coil A side coil st 2 st 2...
  • Page 16 SOLENOID VALVE Series SVA20 Series Solenoid Valve ■ Weight List Valve Type Weight (g) Manifold Type Exhaust Type Wiring Weight (g) SVA 20S 84.5 One Side Block Tube Exhaust Individual Connector 154.5 SVA 20D 120.5 One Side Block Tube Exhaust 9 Pins Sub-D connector 178.5...
  • Page 17 /www. ■ Use the following formula to calculate the weight of SVA20 Series. (Manifold-base x Station Qty) + Manifold Type + (Cartridge Fitting x Qty) + (Individual Connector Cable x Qty) + (Valve Type x Qty) Example 1 SVA 2005 ①...
  • Page 18 SOLENOID VALVE Series SVA20 Series Solenoid Valve ■ Flow Characteristics 1(P) Port:φ12mm 1(P) Port:φ12mm Output Pressure Output Pressure 4(A)・2(B) Port:φ6mm 4(A)・2(B) Port:φ8mm (MPa) 0.7 (MPa) 0.7 Intake Pressure Intake Pressure (MPa) (MPa) 1000 1200 1400 Flow Rate (l/min(ANR)) Flow Rate (l/min(ANR))
  • Page 19 /www. ■ Standard Size List Refer to the Refer to the Type Port Fitting Type Tube O.D. Type Port Fitting Type Tube O.D. pages below pages below Sub-D connector ø1/4 Sub-D connector ø1/4 Output port Output port Intake &...
  • Page 20 SOLENOID VALVE Series SVA20 Series Solenoid Valve ■ Sub-D Connector Intake & Exhaust Block on Both Sides Unit:mm Tube Exhaust 51.5 Model Code Push-Lock Manual Button file name Sub-D Connector SVA-016 SVA-018 Screw Hole for 2-M4 SVA-028 SVA20□A-□□□□-D□-□□-□-□□ SVA-030 SVA-038 20.5...
  • Page 21 /www. Intake & Exhaust Block on Both Sides Unit:mm Open-air Exhaust Sub-D Connector Exhaust Window Model Code 51.5 file name Push-Lock Manual Button SVA-016 SVA-018 Screw Hole for 2-M4 SVA-028 SVA20□A-□□□S-D□-□□-□-□□ SVA-030 SVA-038 20.5 P=16 20.5...
  • Page 22 SOLENOID VALVE Series SVA20 Series Solenoid Valve ■ Individual Plug-in Connector Intake & Exhaust Block on Both Sides Unit:mm Tube Exhaust Model Code file name 51.5 SVA-014 Connector SVA-026 Push-Lock Manual Button SVA20□A-□□□□-S□-□□-□-□□ SVA-038 Screw Hole for 2-M4 20.5 P=16 20.5...
  • Page 23 /www. Intake & Exhaust Block on Both Sides Unit:mm Open-air Exhaust Model Code file name 51.5 SVA-014 Connector SVA-026 SVA20□A-□□□S-S□-□□-□-□□ Push-Lock Manual Button Exhaust Window SVA-038 Screw Hole for 2-M4 20.5 P=16 20.5 16n+41(n = # of stations)
  • Page 24 SOLENOID VALVE Series SVA20 Series Solenoid Valve ■ Flat (Ribbon) Cable Connector Intake & Exhaust Block Both Sides Unit:mm Tube Exhaust Triangle Mark Model Code Flat (Ribbon) Cable Connector (Conforming to MIL-C-83503) 51.5 file name Push-Lock Manual Button SVA-020 SVA-022...
  • Page 25 /www. Intake & Exhaust Block on Both Sides Unit:mm Open-air Exhaust Triangle Mark 51.5 Flat (Ribbon) Cable Connector (Conforming to MIL-C-83503) Model Code file name Exhaust Window Push-Lock Manual Button SVA-020 SVA-022 Screw Hole for 2-M4...
  • Page 26: Din Rail Mounting Bracket

    ■ DIN Rail Mounting Bracket DIN Rail Mounting Bracket DRF35S Model Code file name SVA-047 DRF35S 97.5 ●Dimension with SVA20 Series mounted (78) 33.5 0.6(Max.) 72.5 2-M4×0.7 2-M3×0.5 (Screw Hole for SVR10 Manifold-base) (Fixing Screw) M4×0.7 (Screw Hole for SVA20 Manifold-base) 37.5...
  • Page 27 /www. ■ Method for Attaching / Detaching DIN Rail Bracket and DIN Rail (1) Fix a solenoid valve on DIN Rail Bracket (DRF35S) by tightening a screw. (*1). *1 Use a screw with the designated size.
  • Page 28: Detailed Safety Instructions

    SVA20 Series Solenoid Valve Detailed Safety Instructions Before using PISCO products, be sure to read “Safety Instructions” and “Safety Instruction Manual” and “Common Safety Instructions for Solenoid Valve Series”. Warning 1. When a solenoid valve is operated under viblation less than 5G, install it so that a spool valve is at a right angle to the vibrating direction.
  • Page 29: Installation

    /www. Safety Rules for Use 1. Air Quality ■ Impurities contained in air may cause malfunctions or troubles of solenoid valves. Remove drain and dust from the supply air. ■ Apply flushing to both supplying and cylinder sides when piping. Place a filter (filtering accuracy: 5μm or less) close to a solenoid valve.
  • Page 30 SOLENOID VALVE Series SVA20 Series Solenoid Valve ② There is a concave niche on the back of the solenoid valve as figure 1 shows. Insert a flathead screwdriver into it and to pull up a solenoid valve as figure 2 shows.
  • Page 31 /www. 8. Replacement of Cartridge Fitting ■ All Fittings at connecting ports(A port & B ports) are ①Lock Pin deatchable. Follow the instructions below. ① Pull up a lock pin with a tool such as a flathead screwdriver and take it out.
  • Page 32 SOLENOID VALVE Series SVA20 Series Solenoid Valve ■ Construction Specification of SVA20 Series(Manifold type) with Sub-D Connector Double Solenoid Valve One Side Intake / Exhaust Port Single Solenoid Valve Fixing Screw for Manifold-base Open-air Exhaust Sub-D Connector Fixing Screw for Solenoid Valve...
  • Page 33 /www. ■ Construction Specification of SVA20 Series (Manifold type) with Individual Plug-in Connector Double Solenoid Valve One Side Intake / Exhaust Port Single Solenoid Valve Fixing Screw for Manifold-base Open-air Exhaust Individual Connector Fixing Screw for Solenoid...
  • Page 34 SOLENOID VALVE Series SVA20 Series Solenoid Valve ■ Construction Specification of SVA20 Series (Manifold type) with Flat (Ribbon) Cable Connector Double Solenoid Valve One Side Intake / Exhaust Port Single Solenoid Valve Fixing Screw for Manifold-base Open-air Exhaust Flat (Ribbon) Cable Connector...
  • Page 35 /www. ■ Related Products of SVA20 Series There are the following related products for SVA20 Series. (Sub-D Connector is only available for Wiring Type: Sub-D Connector. When Individual Plug-in Connector is selected, Individual Plug-in Connectors are accompanied by, but Flat (Ribbon) Cable is Not accompanied.
  • Page 36 SOLENOID VALVE Series SVA20 Series Solenoid Valve...
  • Page 37: Safety Instructions

    JIS B 8370:General rules and safety requirements for systems and their components. This safety instructions is classified into “Danger”, “Warning” and “Caution” depending on the degree of danger or damages caused by improper use of PISCO products. Danger Hazardous conditions. It can cause death or serious personal injury.
  • Page 38 PISCO products, or by combinational use with non-PISCO products and other software systems. 5. The damages caused by the defect of Pisco products shall be covered but limited to the full amount of the PISCO products paid by the customer.
  • Page 39 2. Do not disassemble or modify PISCO products, which affect the performance, function, and basic structure of the product. 3. Turn off the power supply, stop the air supply to PISCO products, and make sure there is no residual air pressure in the pipes before maintenance and inspection.
  • Page 40 When a fluid medium is liquid or the products are required to be used in harsh environments, contact us for further information. 5. In case of using non-PISCO brand tubes, make sure the tolerance of the outer tube diameter is within the limits of Table 1.
  • Page 41 ③ Adjust the tube direction while tightening thread within these limits, since some PISCO products are not rotatable after the installation. ● Table 2: Recommended tightening torque / Sealock color / Gasket...
  • Page 42 /www. Common Safety Instructions for Solenoid Valve Series Before selecting or using PISCO products, read the following instructions. Read the detailed instructions for individual series. Warning 1. When piping, pipe flushing is required for pipes at both air supply and actuator sides.
  • Page 43 SOLENOID VALVE Series Caution 1. A solenoid valve allows air leakage. Do not use the valve for applications which requires air tightness. 2. Do not use a solenoid valve for a large air-blow. A drop of inner pressure can cause the internally pilotted-valve structure malfunctions. 3.