WATER CONDENSATION DRAINAGE

When there is excess water condensation inside the unit, the Portable Air Conditioner stops running
and shows an error code "P1" with an alarm. This indicates that the water condensation needs to be
drained using the following procedures:
Manual Draining in Cooling, Dehumidifying and Auto Modes
Water may need to be drained in high humidity areas.
1.
Unplug the unit from power source.
2.
Place a drain pan under the lower rubber drain plug.
See diagram.
3.
Remove the drain plug cap.
4.
Water will drain out and collect in the drain pan.
5.
After the water is drained, replace the drain plug cap.
6.
You can now turn on the unit.
Continuous Draining in Dehumidifier Mode
While using the unit in dehumidifier mode, continuous drainage is recommended.
1.
Unplug the unit from power source.
2.
Remove the upper drain plug cap.
Some residual water may spill so please have a pan to
collect the water.
3.
Connect the drain tube (included) to the upper drain
plug. See diagram.
4.
The water can be continuously drained through the
drain tube into a floor drain or bucket.
5.
Replace the drain plug cap.
6.
You can now turn on the unit.
IMPORTANT: It is NOT recommended to connect the drain hose for continuous drainage while the
unit is switched ON in air conditioning cooling mode. Doing so can reduce the cooling efficiency
of the Portable Air Conditioner. Only drain the water condensation when the unit is switched off.
Continuous drainage is only suitable when the unit is set up in Dehumidifier mode.
Drain Tube (included):
Dia. 0.6" (1.6 cm)
Length: 23.6" (60 cm)
EN
13
Lower
Rubber
Drain Plug
Drain Pan
(included)
Upper Rubber
Drain Plug