1.4 Datalogger mounting 
Dataloggers can be mounted: 
On a wall: mounting brackets are available as additional accessories.
On a metallic structure: strong magnets are available as additional accessories.
On a pole: plates for 35 and 50 mm pole diameters are available as additional accessories for this
mounting type.
Inside a manhole (with a plastic or metallic cover): no special accessories are available for this mounting
type. Even though the dataloggers are IP67 certified, we recommend installing them in holes with
proper drainage so that they won't be permanently covered with
All  GTecLink  dataloggers  are  protected  against  lightning  and  there  is  an  easy-to-use 
grounding  screw (Figure 4) next to the cable glands, which may be connected to provide
protection.
Note ​ : In order to protect the datalogger from surges (especially in installations with long  cable runs) the
datalogger must be properly grounded via connection to the grounding screw.
GTecLink Datalogger Manual
Figure 4: Detail of the grounding screw 