Installing of Assembled Filter and Crumb Catcher
•
Put the assembled filter in the filter pan.
Add Magnesol (Skip this step if your restaurant doesn't use Magnesol)
•
Measure 180 g Magnesol
Key Point
•
Sprinkle the Magnesol® powder evenly inside the assembled filter pan.
•
Put the crumb catcher on top of the filter pan and position it against the standpipe.
•
Ensure the crumb catcher remains against the standpipe and slide the filter pan cover,
over the filter pan.
Slide the tank under the cooker
•
Slide the tank back under the cooker, and join the standpipe to the connecting union.
•
Hand-tighten union.
Install condensation drain pan
•
Install the condensation drain pan in front of the filter pan.
®
using the Magnesol measuring cup provided.
For ease of operation preportion the Magnesol powder.
Weigh out 180 g using a calibrated scale.