Installation instruction for radial blowers for areas subject to gas and dust explosion hazards
6.4

Blower mounting

Attention! Potential for damage to the equipment!
A double sided mounting must be avoided. This can result in damage and failure of blower
components.
Decouple the structure bound sound by installing a canvas expansion sleeve.
The blower may only be mounted using one location! Either at the exhaust flange, the blower
base and/or motor console or at the intake mounting flange.
Installation examples:
At the exhaust flange
At the intake mounting flange for wall installation
07/2019 KARL KLEIN Ventilatorenbau GmbH
at the motor console
005_KL01_01